BIS Menu  |  After Hours Variance Permits  |  Property Profile  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y080435
Premises: 2551 WEBSTER AVENUE BRONX BIN: 2016332     Block: 3275   Lot: 103
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 2551 WEBSTER AV Census Tract:   397 Health Area:  1000
BASEMENT Admin Area:   Y - BRONX Inspection Area:   I
BRONX, NY 10458 Community Board:   207
DOB Cross Street(s):   EAST FORDHAM ROAD,    EAST 193 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/13/1996 Job Start Date:   11/05/1996
Last Change:   08/22/2025 Job End Date:   11/30/1996
Appointment Status:   
Last Inspection By:   GARY MCCALLA       On     03/13/2003      
Field Disp:   N - NO ACCESS
Energize Recommendation:  
Objection Disposition:  

License #: 010417 Licensee Name: JAMES J HAMMEL
Firm: 000743 Firm Name: JAMES J. HAMMEL
Firm Phone: 718-788-5811  Firm Address: 480 11TH STREET BROOKLYN NY 11215 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $365.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   X
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: JAFFE WEBSTER PROPERTIES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  3  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  3  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 2 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/13/1996 Notice:  
Power Issued: 11/13/1996 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y080435
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/13/1996 12/17/1996 RT1 P (30) (0)
INSPECTION COMMENTS: SVC NOT ACCESSED
 
(2) 12/26/1997 01/12/1998 RT1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 01/28/1998 02/02/1998 RT1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 01/29/2002 01/30/2002 GYM N (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 11/18/2002 11/22/2002 GYM N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 01/08/2003 01/14/2003 GYM N (20) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 03/13/2003 03/18/2003 GYM N (20) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  After Hours Variance Permits  |  Property Profile  |  Electrical Inspection Work Order  |  Back