Electrical Application Details for App #: Y076342
Premises: 2254 GRAND CONCOURSE BRONX BIN: 2013722     Block: 3158   Lot: 15
   
Application Completed and Certified

Filed: 2254 GRAND CONCOURSE Census Tract:   383 Health Area:  1000
BUILDING Admin Area:   Y - BRONX Inspection Area:   I
BRONX, NY 10457 Community Board:   205
DOB Cross Street(s):   EAST 182 STREET,    EAST 183 STREET
Status:   C - JOB IS SIGNED OFF 03/17/1998
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   02/23/1996 Job Start Date:   01/04/1996
Last Change:   12/15/1998 Job End Date:   06/05/1996
Appointment Status:   
Last Inspection By:   TERRETT, R.       On     02/18/1998      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 009873 Licensee Name: JOE MIDDLETON
Firm: 001933 Firm Name: NORWAY ELECTRIC CORP.
Firm Phone: 718-992-5500  Firm Address: 1205 JEROME AVENUE BRONX NY 10452 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $741.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: DOUGERT MGT
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  13  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  13  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 94  168  24  84  99                
Total Units : 469 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   10AM TO 3PM Contact Phone:   718 992-5500

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 13 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 02/23/1996 Notice: 1 - FIRST NOTICE 11/24/1997
Power Issued: 02/23/1996 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: INSTALLED 1 EDISON BOX, INSTALLED 1 400 AMP SS,REWIRE BUILDING COMPL
Contractor's Comments:  BUILDING

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y076342
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/02/1997 05/16/1997 RT1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 11/20/1997 11/24/1997 IA1 V G (105) (6) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 02/18/1998 02/19/1998 RT1 C R E (90) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application