Electrical Application Details for App #: Y073974
Premises: 653 BRUCKNER BOULEVARD BRONX BIN: 2004139     Block: 2603   Lot: 115
   
Application Completed and Certified

Filed: 653 BRUCKNER BLVD Census Tract:   83 Health Area:  4200
1ST FLOOR Admin Area:   Y - BRONX Inspection Area:   C
BRONX, NY 10455 Community Board:   202
DOB Cross Street(s):   AUSTIN PLACE,    TIMPSON PLACE
Status:   C - JOB IS SIGNED OFF 02/15/2000
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/31/1995 Job Start Date:   08/31/1995
Last Change:   01/12/2000 Job End Date:   08/31/1995
Appointment Status:   
Last Inspection By:   TERRETT, R.       On     01/08/2000      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010241 Licensee Name: VINCENT LUCCARELLI
Firm: 001368 Firm Name: SQUARE ELECTRIC CO., INC.
Firm Phone: 718-892-7100  Firm Address: 3028 E. TREMONT AVENUE BRONX NY 10461 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $480.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   WAREHOUSE & OFFICES
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: FRANK FERROVECHIO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  4  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   MONDAY THRU FRIDAY 8AM TO 5PM Contact Phone:   (718) 892-7100

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 8 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/31/1995 Notice:  
Power Issued: 08/31/1995 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y073974
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/04/1996 03/13/1996 AA1 P (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 05/14/1997 05/19/1997 AA1 P (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 01/08/2000 01/12/2000 RT1 C E (30) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Elevators  |  Electrical Inspection Work Order  |  Back