BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y052051
Premises: 1888 JEROME AVENUE BRONX BIN: 2008233     Block: 2852   Lot: 9
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 1890 JEROME AV Census Tract:   233.01 Health Area:  2310
BSMT Admin Area:   Y - BRONX Inspection Area:   E
BRONX, NY 10453 Community Board:   205
DOB Cross Street(s):   MOUNT HOPE PLACE,    WEST 177 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   05/29/1992 Job Start Date:   01/22/1992
Last Change:   08/22/2025 Job End Date:   02/18/1992
Appointment Status:   
Last Inspection By:   PRIVATE AGENCY       On     08/25/1997      
Field Disp:   H - NO PROGRESS ON JOB
Energize Recommendation:  
Objection Disposition:  X - NOT REMOVED

License #: 010887 Licensee Name: HUGO A PALAVICINO
Firm: 002169 Firm Name: PRESTIGE ELECTRIC CORP.
Firm Phone: 718-584-3784  Firm Address: 341 LAFAYETTE STREET NEW YORK NY 10012 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $48.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   NOT GIVEN
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: JOE DOE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 05/29/1992 Notice: C - CALL TO OFFICE 09/17/1997
Power Issued: 05/29/1992 Response:  

Follow-Up:
Wires Comments: INSTALLE 100AMP S.S ONLY EXISTING METERS
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y052051
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/04/1994 09/05/1995 X01 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 12/01/1995 12/21/1995 AA1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 12/29/1995 01/18/1996 AA1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 01/30/1996 02/07/1996 AA1 P (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 08/25/1997 09/17/1997 X01 H X (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back