Electrical Application Details for App #: Y018056
Premises: 1980 UNIONPORT ROAD BRONX BIN: 2047876     Block: 4256   Lot: 14
   
Application Completed and Certified

Filed: 2001 WHITE PLAINS RD Census Tract:   230 Health Area:  1210
NONE Admin Area:   Y - BRONX Inspection Area:   I
BRONX, NY 10462 Community Board:   211
DOB Cross Street(s):   BIRCHALL AVENUE,    UNIONPORT ROAD
Status:   C - JOB IS SIGNED OFF 01/23/1992
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/28/1988 Job Start Date:   01/26/1988
Last Change:   01/23/1992 Job End Date:   02/26/1988
Appointment Status:   
Last Inspection By:   SIMETI, S.       On     01/15/1992      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  R - REMOVED

License #: 010277 Licensee Name: V RICCI
Firm: 001484 Firm Name: VINCENT RICCI
Firm Phone: 718-828-6218  Firm Address: 503 EDISON AVENUE BRONX NY 10465 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $58.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   DELI
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: TRIBORO INVESTORS INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 12                
Total Units : 36 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 11/15/1991 Notice:  11/15/1991
Power Issued: 01/28/1988 Response: R - REINSPECTION 12/11/1991

Follow-Up: K - (CLOSED)
Wires Comments: RESTORE WIRING FIRE DAMAGED SERV IN TACT CON ED REMOVED METER
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y018056
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/04/1991 11/15/1991 SS1 A B (65) (4)
INSPECTION COMMENTS: NONE
 
(2) 01/15/1992 01/23/1992 SS1 C R G (40) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application