Electrical Application Details for App #: Y014163
Premises: 3046 HOLLAND AVENUE BRONX BIN: 2055612     Block: 4570   Lot: 23
   
Application Completed and Certified

Filed: 3046 HOLLAND AV Census Tract:   338 Health Area:  0810
BOILER ROOM Admin Area:   Y - BRONX Inspection Area:   G
BRONX, NY 10467 Community Board:   212
DOB Cross Street(s):   ADEE AVENUE,    BURKE AVENUE
Status:   C - JOB IS SIGNED OFF 09/21/1988
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/26/1987 Job Start Date:   08/28/1987
Last Change:   09/21/1988 Job End Date:   08/28/1987
Appointment Status:   
Last Inspection By:   BOARD, K.       On     09/08/1988      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010620 Licensee Name: RUDY N WINKLER
Firm: 001537 Firm Name: WINKLER ELEC'L CONTR'G. C
Firm Phone: 212-381-9462  Firm Address: 865 WOODWARD AVENUE QUEENS NY 11385 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
9 - OTHER
Total Fee:  $36.00
Other Work:   BOILER WIRING ONLY
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: ADHAR REALTY CO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                     
Total Units : 2 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y014163
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/04/1987 12/08/1987 RT1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 12/30/1987 01/05/1988 JST P (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 09/08/1988 09/21/1988 KCB C (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application