Electrical Application Details for App #: Y006758
Premises: 378 EAST 161 STREET BRONX BIN: 2001784     Block: 2407   Lot: 13
   
Application Completed and Certified

Filed: 378 E 161 ST Census Tract:   141 Health Area:  3400
ENTIRE Admin Area:   Y - BRONX Inspection Area:   C
BRONX, NY 10451 Community Board:   203
DOB Cross Street(s):   COURTLANDT AVENUE,    MELROSE AVENUE
Status:   C - JOB IS SIGNED OFF 02/18/1988
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/19/1986 Job Start Date:   10/15/1986
Last Change:   02/05/1988 Job End Date:   11/15/1986
Appointment Status:   
Last Inspection By:   BELLINGER, Z.       On     02/02/1988      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010495 Licensee Name: CHARLES LUCCARELLI
Firm: 001648 Firm Name: EXPRESS ELECTRIC CO.
Firm Phone: 718-792-7000  Firm Address: 3473 STEENWICK AVENUE BRONX NY 10475 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $117.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   RETAIL
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: FRED FUCHO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 20  18      20              
Total Units : 61 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 01/02/1987 Notice:  04/02/1987
Power Issued: 01/02/1987 Response: R - REINSPECTION 04/16/1987

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y006758
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/27/1987 04/02/1987 KCB V G (45) (1)
INSPECTION COMMENTS: NEUTRAL NOT BONDED TO S. SW BONDED BSMT SERVICE ENCLOSET
 
(2) 05/15/1987 06/04/1987 OA1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 06/26/1987 07/14/1987 OA1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 08/07/1987 08/21/1987 OA1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 09/18/1987 10/02/1987 OA1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 10/30/1987 11/17/1987 OA1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 12/11/1987 12/31/1987 ZB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 02/02/1988 02/05/1988 ZB1 C R E (90) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.