BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: X14661
Premises: 460 EAST 138 STREET BRONX BIN: 2000251     Block: 2282   Lot: 30
   
Application Completed and Certified

Filed: 460 E 138 ST Census Tract:   25 Health Area:  4500
BASEMENT Admin Area:   Y - BRONX Inspection Area:   A
BRONX, NY 10454 Community Board:   201
DOB Cross Street(s):   WILLIS AVENUE,    BROWN PLACE
Status:   C - JOB IS SIGNED OFF 04/28/1989
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/21/1986 Job Start Date:   12/23/1985
Last Change:   04/06/1989 Job End Date:   01/05/1986
Appointment Status:   
Last Inspection By:   POTTS, JAMES       On     03/30/1989      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 009882 Licensee Name: J RISHIK
Firm: 000733 Firm Name: J.R.C. ELECTRIC, INC.
Firm Phone: 212-665-5436  Firm Address: 370 EAST 134TH STREET BRONX NY 10454 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $65.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: MOTT HAVEN REALTY ASSOC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 5 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: 1 200A SERV EQUIPMT 5 3 WIRE METERS
Contractor's Comments:  E 500

 
Inspection Details
 

INSPECTION FOR APPLICATION #: X14661
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/04/1986 JB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 04/17/1987 05/31/1988 OA1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 06/24/1988 07/13/1988 ZB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 08/17/1988 08/24/1988 CB1 N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 09/21/1988 09/26/1988 RT1 J G (60) (0)
INSPECTION COMMENTS: NONE
 
(6) 11/25/1988 12/16/1988 CB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 03/30/1989 04/06/1989 JP1 C (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order