BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: S02817B
Premises: 273 LINCOLN AVENUE STATEN ISLAND BIN: 5109587     Block: 3591   Lot: 8
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 273 LINCOLN AV Census Tract:   114.02 Health Area:  0910
BSMT Admin Area:   R - STATEN ISLAND Inspection Area:   C
STATEN IS, NY 10306 Community Board:   502
DOB Cross Street(s):   GRANT PLACE,    HYLAN PLACE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   06/24/1985 Job Start Date:   09/12/1983
Last Change:   08/22/2025 Job End Date:   09/12/1983
Appointment Status:   
Last Inspection By:   TAKOS, M.       On     07/13/1993      
Field Disp:   H - NO PROGRESS ON JOB
Energize Recommendation:  B - CANCEL POWER AUTH
Objection Disposition:  X - NOT REMOVED

License #: 010361 Licensee Name: PETER CATELLO
Firm: 000304 Firm Name: CATELLO ELEC'L CONT., INC
Firm Phone: 718-356-3033  Firm Address: 516 1-A INDUSTRIAL LOOP STATEN ISLAND NY 10309 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $27.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: PRASKACH
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 07/22/1993 Notice: C - CALL TO OFFICE 07/22/1993
Power Issued: Response:  

Follow-Up:
Wires Comments: 2-O.D.METER 2-100A SVC EQUIP.
Contractor's Comments:  E 500

 
Inspection Details
 

INSPECTION FOR APPLICATION #: S02817B
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/01/1985 PR1 N G (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 05/05/1986 05/15/1986 PR1 A B (35) (1)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 05/19/1987 06/02/1987 PCM H X B (30) (0)
INSPECTION COMMENTS: CTO
 
(4) 11/13/1987 11/24/1987 GO1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 09/29/1989 10/06/1989 AG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 05/25/1990 06/15/1990 PCM Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 09/13/1991 10/07/1991 RM1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 10/25/1991 10/28/1991 RM1 N (30) (0)
INSPECTION COMMENTS: NONE
 
(9) 08/15/1992 08/20/1992 GAT N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 03/20/1993 03/22/1993 JBF N (15) (0)
INSPECTION COMMENTS: VIOL TO OWNER
 
(11) 06/04/1993 06/15/1993 MT1 N (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(12) 07/13/1993 07/22/1993 MT1 H X B (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application