BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Q20598
Premises: 42-22 NATIONAL STREET QUEENS BIN: 4040515     Block:    Lot:
   
Application Completed and Certified

Filed: 99-27 43 AV Census Tract:   407 Health Area:  1100
NOT GVN Admin Area:   A - QUEENS Inspection Area:   D
QUEENS, NY 11368 Community Board:   404
DOB Cross Street(s):    99 STREET,    NATIONAL STREET
Status:   C - JOB IS SIGNED OFF 09/24/1986
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/03/1986 Job Start Date:   12/31/1985
Last Change:   09/24/1986 Job End Date:   01/31/1986
Appointment Status:   
Last Inspection By:   DEUTSCHER, L.       On     09/20/1986      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010497 Licensee Name: GEORGE PRASSAKOS
Firm: 001652 Firm Name: ACG ELEC'L CONTR'S INC.
Firm Phone: 718-445-2115  Firm Address: 31-11 FARRINGTON STREET FLUSHING NY 11354 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $149.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   X
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: AFZAL SHEIKH/96-32 46 AVE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  1  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: Notice:  
Power Issued: 01/13/1986 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: 1-200A 1JAW METER/1-200A SV.EQ./#2/0 FDR/2/0 SUB-FDR
Contractor's Comments:  E 500

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Q20598
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 04/04/1986 04/22/1986 LD1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 05/22/1986 06/07/1986 LD1 N (15) (0)
INSPECTION COMMENTS: NO ACCESS
 
(4) 09/20/1986 09/24/1986 LD1 C (50) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back