Electrical Application Details for App #: M404273
Premises: 214 WEST 24 STREET MANHATTAN BIN: 1014159     Block: 773   Lot: 56
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 220 W 24TH ST Census Tract:   91 Health Area:  5200
APTS 2R, 3M Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10011 Community Board:   104
DOB Cross Street(s):    7 AVENUE,    8 AVENUE
Status:   C - JOB IS SIGNED OFF 03/08/2019
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/16/2017 4:10 PM
Application Entered:   11/16/2017 Job Start Date:   11/16/2017
Last Change:   03/08/2019 Job End Date:   11/16/2018
Appointment Status:   
Last Inspection By:   DHANESHWAR BISSOON       On     02/22/2019      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011601 Licensee Name: VITO INGRAVALLO
Firm: 004690 Firm Name: GALAXY ELECTRIC CORP
Firm Phone: 718-833-7171  Firm Address: 6502 11TH AVE 1ST FLOOR BROOKLYN NY 11219 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $136.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MARK EHRENREICH
Owner Business Name: AKELIUS RE MANAGEMENT LLC
Authorized Representative:  MARK EHRENREICH
Relationship To Owner:   SELF


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  (2) 80A
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  (2) 2/3
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  125A
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002  2R  14  13  14           
003  3M  11  12  11           
Buildings Total 25  25  12  25              
Total Units : 93 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 01/14/2019
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M404273
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/14/2019 01/14/2019 DWB V (70) (5)
INSPECTION COMMENTS: OBJECTION ISSUED, CONTRACTOR DID NOT INSTALL MOTOR.
 
(2) 02/22/2019 02/22/2019 DWB C R (45) (0)
INSPECTION COMMENTS: NO OBJECTION ISSUED.

OBJECTION FOR APPLICATION #: M404273
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
(FLOOR: 003) 210.52, RECEPTACLE NOT PROVIDED FOR WALL SPACE.
RSLV 01/14/2019 01/14/2019 02/22/2019
 
002 ( 53) GFCI HAS NOT BEEN PROVIDED
(ALL FLOORS)210.8, AT BATH RM, MIRROR RECEPTACLE ARE NOT GFCI PROTECTED,THRU-OUT,
RSLV 01/14/2019 01/14/2019 02/22/2019
 
003 (999) OTHER
(ALL FLOORS)410.144, LED LIGHT, TRANSFORMER MUST BE ACCESSIBLE AFTERINSTALLATION, THRU-OUT.
RSLV 01/14/2019 01/14/2019 02/22/2019
 
004 ( 29) OUTLET BOXES ARE NOT COVERED
(BASEMENT) 314.25, JUNCTION BOX FOR FEEDER ARE NOT COVER.
RSLV 01/14/2019 01/14/2019 02/22/2019
 
005 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(BASEMENT) 408.4, FEEDER PANEL, NO DIRECTORY PROVIDED.
RSLV 01/14/2019 01/14/2019 02/22/2019