Electrical Application Details for App #: M402898
Premises: 8 EAST 110 STREET MANHATTAN BIN: 1051606     Block: 1615   Lot: 60
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 8 E 110 ST Census Tract:   174.01 Health Area:  2500
1F - 5F 1G-5G 1H 1A 1B 1C 1D Admin Area:   M - MANHATTAN Inspection Area:   H
NEW YORK, NY 10029 Community Board:   111
DOB Cross Street(s):   FRAWLEY CIRCLE,    MADISON AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/17/2017 4:30 PM
Application Entered:   10/17/2017 Job Start Date:   10/17/2017
Last Change:   08/22/2025 Job End Date:   10/17/2018
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   GARY MCCALLA       On     03/20/2019      
Field Disp:   J - JOB IN PROGRESS
Energize Recommendation:  
Objection Disposition:  

License #: 012571 Licensee Name: PANDELI GJINI
Firm: 003543 Firm Name: TECHNO-VOLT ELEC, INC
Firm Phone: 718-359-8070  Firm Address: 28-29 119TH STREET FLUSHING NY 11354 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $161.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: HOPE EAST OF FIFTH LLC
Authorized Representative:  ANTHONY DIGUGLIELMO
Relationship To Owner:   GENERAL CONTRACTOR


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND                       
001  49  140  21  17               
002  14  40               
003  14  40               
004  14  40               
005  14  40               
Buildings Total 105  300  45  45                  
Total Units : 495 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  RELOCATE EXISTING WIRING FOR OUTLET AND SWITCHES REPLACE CARBON MONOXIDE LOWER THE SWITCHES TO 44" AND RAISE THE OUTLETS TO 22" REPLACE EXISTING LIGHTS. REMOVAL OF ECB VIOLATION #35274125J

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M402898
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/30/2019 01/31/2019 DWB N (30) (0) Y
INSPECTION COMMENTS: CALL CONTRACTOR, NO SHOW
 
(2) 03/20/2019 03/20/2019 GYM J (70) (0) Y
INSPECTION COMMENTS: NEED ACCESS TO ALL APTS.