BIS Menu  |  Elevators  |  DOB Violations  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M401629
Premises: 432 PARK AVENUE MANHATTAN BIN: 1088817     Block: 1292   Lot: 33
   

DOB NOW: Inspections


Filed: 432 PARK AV Census Tract:   112.02 Health Area:  4800
59A Admin Area:   M - MANHATTAN Inspection Area:   L
NEW YORK, NY 10022 Community Board:   105
DOB Cross Street(s):   EAST 56 STREET,    EAST 57 STREET
Status:   K - CLOSED/CANCELLED 12/04/2020
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/18/2017 4:24 PM
Application Entered:   09/18/2017 Job Start Date:   09/19/2017
Last Change:   12/04/2020 Job End Date:   03/10/2018
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   SCHULER, THOMAS       On     12/04/2020      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012704 Licensee Name: PIOTR MISA
Firm: 004541 Firm Name: P & Z ELECTRIC CORP
Firm Phone: 718-360-0858  Firm Address: 3606 37TH STREET ASTORIA NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $65.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: 56TH AND PARK AVE OWNER L
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
059  59A  53      53             
Buildings Total 53      53                
Total Units : 111 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 08/27/2020
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M401629
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/17/2020 07/22/2020 CBK N (30) (0) Y
INSPECTION COMMENTS: DID NOT SEE ELECTRICIAN
 
(2) 08/26/2020 08/27/2020 DWB V (50) (1)
INSPECTION COMMENTS: INSPECTION COMPLETE, CONTRACTOR NEED TO CHANGE APPS, FOR FLOOR DESCRIPTION QUANTITY.
 
(3) 12/04/2020 12/04/2020 TUR K R (1) (0)
INSPECTION COMMENTS: SEE REQ COMMENT

OBJECTION FOR APPLICATION #: M401629
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 059)PAA REQUIRE, CONTRACTOR NEED TO ADD, FLOOR DESCRIPTIONS, 106 LIGHTFIXTURE, 5 SW.
RSLV 08/26/2020 08/26/2020 12/04/2020



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Elevators  |  DOB Violations  |  Electrical Inspection Work Order  |  Back