BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M400981
Premises: 617 GREENWICH STREET MANHATTAN BIN: 1089824     Block: 602   Lot: 55
   

DOB NOW: Inspections


Filed: 621 GREENWICH ST Census Tract:   69 Health Area:  6400
ALL BUILDING Admin Area:   M - MANHATTAN Inspection Area:   R
NEW YORK, NY 10014 Community Board:   102
Related Job Number:    122622947
DOB Cross Street(s):   LEROY STREET,    MORTON STREET
Status:   K - CLOSED/CANCELLED 09/28/2020
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/31/2017 5:36 PM
Application Entered:   08/31/2017 Job Start Date:   08/31/2017
Last Change:   09/28/2020 Job End Date:   08/31/2019
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   DHANESHWAR BISSOON       On     09/28/2020      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 012079 Licensee Name: DARIUSZ GRYGLEWSKI
Firm: 004264 Firm Name: FSM ELECTRICAL CORPORATIO
Firm Phone: 718-482-9151  Firm Address: 11-20 37TH AVENUE LONG ISLAND CITY NY 11101 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
8 - BOILER/BURNER WIRING
L - LIGHTING WORK
T - TEMPORARY LIGHT & POWER
Total Fee:  $741.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  122622947
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: KEVIN MALONEY
Owner Business Name: PMG LEROY STREET DEVELOP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  3P-400A
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  3  2X4#3/0,1X4#3
D. Over 250 MCM  2  4#500MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  3  3P-200A,3P-100A
D. 3 Phase Over 225 AMPS  1  3P-400A 42P
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    18    26  14     
001    36    43     
002    27    10  44     
003    28    27     
ROF      17         
ROF  BH           
Buildings Total 18  112    35  145     37         
Total Units : 356 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 1 - Removed Meters 0 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/31/2017 Notice:  
Power Issued: 08/31/2017 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M400981
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/28/2020 09/28/2020 DWB K (27) (0) Y
INSPECTION COMMENTS: OK TO WITHDRAWAL.