Electrical Application Details for App #: M397913
Premises: 20 HUDSON YARDS MANHATTAN BIN: 1088961     Block: 702   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 500 W 33RD ST Census Tract:   99 Health Area:  5500
FLOORS 13-17 Admin Area:   M - MANHATTAN Inspection Area:   Q
NEW YORK, NY 10001 Community Board:   104
Special Place Name:   HUDSON YARDS TOWER A
DOB Cross Street(s):    10 AVENUE,    HUDSON BOULEVARD EAST
Status:   C - JOB IS SIGNED OFF 02/03/2020
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/28/2017 11:34 AM
Application Entered:   06/28/2017 Job Start Date:   06/28/2017
Last Change:   02/03/2020 Job End Date:   11/15/2018
Appointment Status:   
Last Inspection By:   SCHULER, THOMAS       On     02/03/2020      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011456 Licensee Name: RALPH OCCHIPINTI
Firm: 000064 Firm Name: ADCO ELEC'L CORP
Firm Phone: 718-494-4400  Firm Address: 201 EDWARD CURRY AVENUE STATEN ISLAND NY 10314 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
L - LIGHTING WORK
Total Fee:  $5,040.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  122999719
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOEL BRENNER
Owner Business Name: TW NY PROPERTIES LLC
Authorized Representative:  JOEL BRENNER
Relationship To Owner:   VICE PRESIDENT


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  129  
B. Over #2 to 1/0  13  
C. Over 1/0 to 250 MCM  60  
D. Over 250 MCM  52  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  152  
D. 3 Phase Over 225 AMPS  52  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
013    400  1003    287  800  178  115      405 
014    452  1120    311  904  184  765      1950 
015    508  2388    320  1016  162  150      450 
016    389  849    287  778  145  80      863 
017    421  854    266  842  175  125      398 
Buildings Total 2170  6214    1471  4340     1235          4066 
Total Units : 19496 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 11/18/2019
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  N/A

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M397913
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/26/2019 02/26/2019 ASK V (367) (3)
INSPECTION COMMENTS: FAIL, SEE OBJECTIONS. INSPECTED FLOORS 13 THROUGH 17. NOTE WORK FLOORS AND THE ACTUAL FLOORS ARE LABELED DIFFERENTLY. 21 IS 17, 20 IS 16, 19 IS 15, 18 IS 14, AND 17 IS 13.
 
(2) 03/27/2019 03/27/2019 PHG V R (60) (1)
INSPECTION COMMENTS: FLOOR WITH 1200 AMP EQUIPMENT AND 750 KVA XFRM NO PUSH BAR PROVIDED
 
(3) 11/08/2019 11/18/2019 TUR V R (1) (1)
INSPECTION COMMENTS: FLOOR 018:999-OTHER IMPROPER DOOR SWING AND NO PUSH BAR PROVIDED FOR FLOORS WITH EQUIPMENT 1200 AMPS AND OVER 110.26 OPEN ? ? 03/27/2019 REWRITTEN TO SELF CERTIFICATION
 
(4) 02/03/2020 02/03/2020 TUR C R (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-20-000003401

OBJECTION FOR APPLICATION #: M397913
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 11) FEEDER CONDUCTORS ARE NOT OF PROPER SIZE
(FLOOR: 016) TABLE 310.16 FEEDERS FOR UPS-20A & SDEM-AUDIO OVERFUSED
RSLV 02/26/2019 02/26/2019 03/27/2019
 
002 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(ALL FLOORS)ART. 410.36(B) LIGHT FIXTURES NOT SECURED IN PLACE THE DROP CEILING.
RSLV 02/26/2019 02/26/2019 03/27/2019
 
003 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(ALL FLOORS)DISCONNECT SWITCHES FOR EM DISCONNECT ARE NOT READILY ACCESSIBLE.
RSLV 02/26/2019 02/26/2019 03/27/2019
 
004 (999) OTHER
(FLOOR: 018)IMPROPER DOOR SWING AND NO PUSH BAR PROVIDED FOR FLOORS WITHEQUIPMENT 1200 AMPS AND OVER 110.26
RSLV 03/27/2019 03/27/2019 11/08/2019
 
005 (999) OTHER
(FLOOR: 018) FLOOR 018:999-OTHER IMPROPER DOOR SWING AND NO PUSH BAR PROVIDEDFOR FLOORS WITH EQUIPMENT 1200 AMPS AND OVER 110.26 OPEN ? ?03/27/2019
RSLV 11/08/2019 11/08/2019 02/03/2020



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.