Premises: 301 EAST 68 STREET MANHATTAN BIN: 1044753     Block: 1443   Lot: 1
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 315 E 68TH ST Census Tract:   118 Health Area:  4400
APPT 4T Admin Area:   M - MANHATTAN Inspection Area:   K
NEW YORK, NY 10065 Community Board:   108
DOB Cross Street(s):    2 AVENUE,    1 AVENUE
Status:   C - JOB IS SIGNED OFF 01/29/2019
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/22/2017 5:50 PM
Application Entered:   06/22/2017 Job Start Date:   06/26/2017
Last Change:   01/29/2019 Job End Date:   06/27/2017
Appointment Status:   
Last Inspection By:   CARLOS CARDONA       On     12/06/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010055 Licensee Name: TERRENCE REILLY
Firm: 002151 Firm Name: REILLY ELECTRICAL INC
Firm Phone: 718-826-1570  Firm Address: 57 GRAVESEND NECK RD BROOKLYN NY 11223 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $77.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: DAN ANDERSON
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
004                       
Buildings Total                       
Total Units : 3 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 06/25/2018
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  ADDING TWO OUTLET AND DISHWASHER LINE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M397695
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/09/2018 02/12/2018 GYM V (85) (6)
INSPECTION COMMENTS: FAIL.
 
(2) 06/25/2018 06/25/2018 EDB V Y (60) (3)
INSPECTION COMMENTS: CONTRACTOR NOT READY FOR INSPECTION. SEE ATTACHMENT.
 
(3) 11/21/2018 11/21/2018 CBK N (22) (0) Y
INSPECTION COMMENTS: FAIL. CONTRACTOR NOT SHOW.
 
(4) 12/06/2018 12/06/2018 CDX C R (45) (0)
INSPECTION COMMENTS: PASS. BY CONTRACTOR COMMENTS HIS WORK WAS RELOCATE ELECTRICAL PANEL AND LAUNDRY BRANCH CTO .

OBJECTION FOR APPLICATION #: M397695
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 004) KITCHEN COUNTERTOP MISSING GFCI 210.8
RSLV 02/09/2018 02/09/2018 12/06/2018
 
002 (999) OTHER
(FLOOR: 004) KITCHEN OUTLET BOXES MISSING BONDING JUMPER 250.146
RSLV 02/09/2018 02/09/2018 06/25/2018
 
003 (999) OTHER
(FLOOR: 004) KITCHEN OUTLET BOXES EXTENDER MISSING 314.20
RSLV 02/09/2018 02/09/2018 12/06/2018
 
004 (999) OTHER
(FLOOR: 004) NEW PANEL INSTALLED IN BATH ROOM 240.24
RSLV 02/09/2018 02/09/2018 12/06/2018
 
005 (999) OTHER
(FLOOR: 004) BURIED BOX 314.29
RSLV 02/09/2018 02/09/2018 12/06/2018
 
006 (999) OTHER
(FLOOR: 004) KITCHEN OUTLET BOXES ZIP & SHEET METAL SCREW'S 250.8
RSLV 02/09/2018 02/09/2018 06/25/2018
 
007 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(FLOOR: 004) NO DIRECTORY IN THE PANEL 408.4
RSLV 06/25/2018 06/25/2018 12/06/2018
 
008 (999) OTHER
(FLOOR: 004) DISH WASHER NOT ON SEPARATE CIRCUIT 220.82
RSLV 06/25/2018 06/25/2018 12/06/2018
 
009 (999) OTHER
(FLOOR: 004) PANEL : MULTIWIRE CIRC. NO GROUPED NO SIMULT. DISC210.4
RSLV 06/25/2018 06/25/2018 12/06/2018