BIS Menu  |  After Hours Variance Permits  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M397427
Premises: 236 WEST 26 STREET MANHATTAN BIN: 1014205     Block: 775   Lot: 60
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 236 W 26TH ST Census Tract:   91 Health Area:  5200
APARTMENT 11 S Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10001 Community Board:   104
DOB Cross Street(s):    7 AVENUE,    8 AVENUE
Status:   C - JOB IS SIGNED OFF 07/13/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/16/2017 7:22 AM
Application Entered:   06/16/2017 Job Start Date:   06/16/2017
Last Change:   07/13/2018 Job End Date:   10/20/2017
Appointment Status:   
Last Inspection By:   MARCIN DUBAJ       On     06/29/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 009165 Licensee Name: CARMINE J CAMENZULI
Firm: 003589 Firm Name: JLC ELEC'L CONTR'G INC
Firm Phone: 718-932-2499  Firm Address: 14-45 BROADWAY LONG ISLAND CITY NY 11106 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $121.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: PAUL SADOWSKI
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  18 CIRCUIT, 3 PHASE, 220
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
011  11 S  15  20  15             
011  11S    35  13  15             
Buildings Total 15  55  20  30                
Total Units : 124 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 06/13/2018
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M397427
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/12/2018 06/13/2018 AYC V (112) (5)
INSPECTION COMMENTS: FAIL
 
(2) 06/29/2018 06/29/2018 MJD C R (40) (0)
INSPECTION COMMENTS: PASS

OBJECTION FOR APPLICATION #: M397427
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (132) EQUIPMENT/MATERIAL IS NOT PROPERLY GROUNDED
(FLOOR: 011)CIRCUIT BREAKER PANEL IS NOT PROPERLY GROUNDED. ART. 300.10
RSLV 06/12/2018 06/12/2018 06/29/2018
 
002 ( 15) FLEXIBLE CORDS USED AS PERMANENT WIRING METHOD
(FLOOR: 011)120 VOLT CLOSET LIGHT FIXTURES HARDWIRED WITH SJ CORD AND SUBJECT TODAMAGE. ART. 400.8
RSLV 06/12/2018 06/12/2018 06/29/2018
 
003 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(FLOOR: 011)COUNTERTOP OUTLET RECESSED MORE THAN 1/4" FROM THE FINISHED SURFACE.ART. 312.3
RSLV 06/12/2018 06/12/2018 06/29/2018
 
004 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(FLOOR: 011)LIGHTING IN OFFICE AREA IS NOT PROPERLY GROUNDED. ART. 250.4
RSLV 06/12/2018 06/12/2018 06/29/2018
 
005 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
(FLOOR: 011)ADEQUATE OUTLETS NOT PROVIDED IN THE SLEEPING AREA. ART.210.52(A)(2)
RSLV 06/12/2018 06/12/2018 06/29/2018



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  After Hours Variance Permits  |  Electrical Inspection Work Order  |  Back