BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M395871
Premises: 194 1 AVENUE MANHATTAN BIN: 1005971     Block: 439   Lot: 7
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 194 1ST AV Census Tract:   34 Health Area:  6200
1STAVE/1/2/3/4 Admin Area:   M - MANHATTAN Inspection Area:   T
NEW YORK, NY 10009 Community Board:   103
DOB Cross Street(s):   EAST 11 STREET,    EAST 12 STREET
Status:   C - JOB IS SIGNED OFF 11/16/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/10/2017 9:35 AM
Application Entered:   05/10/2017 Job Start Date:   05/10/2017
Last Change:   11/16/2017 Job End Date:   05/10/2018
Appointment Status:   
Last Inspection By:   MCPARTLAND, BRIAN       On     11/13/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012361 Licensee Name: ANGELO DOMINGUEZ
Firm: 004263 Firm Name: ALLTECH ELECL CONTNG CORP
Firm Phone: 646-491-2088  Firm Address: 227 SEA BREEZE AVE., STE 201 BROOKLYN NY 11224 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $470.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: 192-4 1ST AVE NPG LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  8  NEW FEEDERS.
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  8  #2 CU, SINGLE-PHASE, 3-WI
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  8  100A, 20CKTS.
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  15  30    15             
002  15  30    15             
002  15  30    15             
003  15  30    15             
003  15  30    15             
004  15  30    15             
004  15  30    15             
ROF                     
Buildings Total 105  210    56  105              
Total Units : 484 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 09/15/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  ALL APARTMENTS ARE BEING REWIRED. |ST FLOOR APT IS NOT BEING WIRED WITH BRANCH CIRCUITRY

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M395871
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/15/2017 06/19/2017 GYM V (55) (2)
INSPECTION COMMENTS: INSPECTED APTS. #8 & # 7 ONLY. SEE APPL. # M397159 M397143 ADD FEEDERS.
 
(2) 09/15/2017 09/15/2017 CLC V R (80) (8)
INSPECTION COMMENTS: INSPECTION FAIL
 
(3) 11/13/2017 11/14/2017 BMP C R (75) (0)
INSPECTION COMMENTS: OBJECTIONS REMOVED. CERTIFIED.

OBJECTION FOR APPLICATION #: M395871
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 005) KITCHENS MISSING GFCI COUNTERTOP 210.8
RSLV 06/15/2017 06/15/2017 09/15/2017
 
002 ( 24) ARMORED CABLES ARE NOT PROPERLY SECURED
(ROOF) FLEXIBLE METAL CONDUITS HVAC.
RSLV 06/15/2017 06/15/2017 09/15/2017
 
003 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(FLOOR: 003) APT 4 PANEL FEEDER CONNECTOR NOT GNDED TO BOX
RSLV 09/15/2017 09/15/2017 11/13/2017
 
004 ( 25) ARMORED CABLES ARE NOT PROPERLY TERMINATED
(FLOOR: 003) APT 3 PANEL CONNECTORS MISSING
RSLV 09/15/2017 09/15/2017 11/13/2017
 
005 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(FLOOR: 005) AC UNITS MC CABLE GROUND NOT BONDED TO BOXES 250.118
RSLV 09/15/2017 09/15/2017 11/13/2017
 
006 (999) OTHER
(FLOOR: 005) SLPICE BOXES FOR AC UNITS NOT ACCESSIBLE 300.15 A
RSLV 09/15/2017 09/15/2017 11/13/2017
 
007 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
(ALL FLOORS) KO MISSING IN PANELS THOUGH OUT APTS
RSLV 09/15/2017 09/15/2017 11/13/2017
 
008 (340) RECEPTACLES NOT TAMPERPROOF
(ALL FLOORS) KITCHEN COUNTER GFCI THOUGH OUT NOT TR 406.11
RSLV 09/15/2017 09/15/2017 11/13/2017
 
009 (999) OTHER
(ROOF) ROOF GCFI NOT WR 406.8 A
RSLV 09/15/2017 09/15/2017 11/13/2017
 
010 (999) OTHER
(ROOF) ROOF SEAL TIGHT SUPPORTS NOT APPROVED 350.30 A
RSLV 09/15/2017 09/15/2017 11/13/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order