BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M395226
Premises: 301 EAST 68 STREET MANHATTAN BIN: 1044753     Block: 1443   Lot: 1
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 315 E 68TH ST Census Tract:   118 Health Area:  4400
2Q Admin Area:   M - MANHATTAN Inspection Area:   K
NEW YORK, NY 10065 Community Board:   108
DOB Cross Street(s):    2 AVENUE,    1 AVENUE
Status:   C - JOB IS SIGNED OFF 12/27/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/26/2017 4:33 PM
Application Entered:   04/26/2017 Job Start Date:   04/27/2017
Last Change:   12/27/2017 Job End Date:   04/27/2018
Appointment Status:   
Last Inspection By:   ALGERNON CHARLES       On     12/27/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012768 Licensee Name: SENAD MEHOVIC
Firm: 004614 Firm Name: E & M ELECTRICAL NY CORP
Firm Phone: 718-281-0158  Firm Address: 193-02 NORTHERN BLVD FLUSHING NY 11358 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $73.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: HOLLI GERSH
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002  2Q    20                 
Buildings Total   20                    
Total Units : 23 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 10/19/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALLING OUTLETS IN LIVING ROOM AND BEDROOM ONLY EVERYTHING ELSE IS EXISTING

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M395226
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/19/2017 10/19/2017 PHG V (35) (4)
INSPECTION COMMENTS: CONTRACTOR TO FIX APP TO REFLECT WORK DID NOT SEE LED DRIVERS FOR BOOK SHELVES
 
(2) 12/27/2017 12/27/2017 AYC C R (45) (0)
INSPECTION COMMENTS: PASS

OBJECTION FOR APPLICATION #: M395226
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (340) RECEPTACLES NOT TAMPERPROOF
(FLOOR: 002) NO TAMPER T OUT 406.11
RSLV 10/19/2017 10/19/2017 12/27/2017
 
002 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(FLOOR: 002) NEW PANEL
RSLV 10/19/2017 10/19/2017 12/27/2017
 
003 (999) OTHER
(FLOOR: 002) BURIED BOX FOR BRANCH WIRING PULL BOX 314.29
RSLV 10/19/2017 10/19/2017 12/27/2017
 
004 (999) OTHER
(FLOOR: 002) AC OUTLETS NOT SIMPLEX TYPE ART 210
RSLV 10/19/2017 10/19/2017 12/27/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back