BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M394896
Premises: 43 EAST 34 STREET MANHATTAN BIN: 1017114     Block: 864   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 20 E 35 ST Census Tract:   74 Health Area:  5200
APT# 15H Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10016 Community Board:   106
DOB Cross Street(s):   MADISON AVENUE,    PARK AVENUE
Status:   C - JOB IS SIGNED OFF 07/26/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/19/2017 11:14 AM
Application Entered:   04/19/2017 Job Start Date:   04/19/2017
Last Change:   07/26/2017 Job End Date:   04/30/2018
Appointment Status:   
Last Inspection By:   RACEWICZ, TOMASZ       On     06/23/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010985 Licensee Name: LINDEN J TUDOR
Firm: 002700 Firm Name: LINTECH ELECTRIC, INC
Firm Phone: 718-941-3766  Firm Address: 3006 TILDEN AVENUE BROOKLYN NY 11226 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $95.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: AMANDA FREITAG
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  24 CKT S/PH PANEL
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
015  15H               
Buildings Total                 
Total Units : 20 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: C - CALL TO OFFICE 06/13/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M394896
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/15/2017 05/18/2017 BMP V (40) (1)
INSPECTION COMMENTS: ACCESS TO OLD PANEL COVERED BY KITCHEN CABINETS. JOB IN PROGRESS.
 
(2) 06/12/2017 06/13/2017 PHG V X (30) (2)
INSPECTION COMMENTS: NO ACCESS DOOR PROVIDED FOR FEEDER PULL BOX AT TIME OF INSPECTION
 
(3) 06/23/2017 06/26/2017 TOR C R (20) (0)
INSPECTION COMMENTS: PASS

OBJECTION FOR APPLICATION #: M394896
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 015)314.29. SPLICES IN OLD PANELBOARD ENCLOSURE IN KITCHEN BELOW AND TOTHE LEFT NEW PANELBOARD NOT ACCESSIBLE.
RSLV 05/15/2017 05/15/2017 06/23/2017
 
002 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(FLOOR: 015) NO GROUND IN FMC PULL BOX TO PANEL 250.118
RSLV 06/12/2017 06/12/2017 06/23/2017
 
003 (999) OTHER
(FLOOR: 015) NO HANDLETIES MULTI WIRE CKT 210.4
RSLV 06/12/2017 06/12/2017 06/23/2017