Electrical Application Details for App #: M394085
Premises: 1101 BROADWAY MANHATTAN BIN: 1015602     Block: 826   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 1107 BROADWAY Census Tract:   58
MEZ, CELL 1-22 Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10010 Community Board:   105
DOB Cross Street(s):    5 AVENUE,    WEST 25 STREET
Status:   C - JOB IS SIGNED OFF 07/26/2022
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   03/30/2017 Job Start Date:   08/01/2013
Last Change:   07/26/2022 Job End Date:   08/01/2013
Appointment Status:   
Last Inspection By:   SCHULER, THOMAS       On     07/24/2022      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011437 Licensee Name: ANTONY GIRONTA
Firm: 002894 Firm Name: AGIR ELEC'L LTD. D/B/A
Firm Phone: 718-846-6200  Firm Address: 130-45 91ST AVENUE PINNACLE ELECTRICAL RICHMOND HILL NY 11418 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
L - LIGHTING WORK
Total Fee:  $5,040.00
Hurricane Sandy Damage:   No
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  104608195
Building Used As:   Z - Commercial/Residential (2  Stores, 128 Apartments)
Special Cert Approval:  
Advisory Board Approval:   REQUIRED
Advisory Board Categories:      K - 1000 KVA SERVICE                            
Advisory Board Approval #:   52088     Submittal #: 13A0628  
Owner / Occup: CRAIG MURPHY
Owner Business Name: MSWG LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  4  4X1000A SWITCH
E. Over 1200 AMPS  2  2X3000A SWITCH
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  30  1/0 AND 2/0 WIRE
D. Over 250 MCM  28  600M CM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  24  11 UP TO 20-1
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  6  11 20-1 PANELS OVER
C. 3 Phase Up to 225 AMPS  6  200A PANELS
D. 3 Phase Over 225 AMPS  4  400A AND 600A PANELS
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    70  65  50  70             
001    75  60  55  75             
MEZ    50  55  45  50             
002    75  60  55  75             
003    75  60  55  75             
004    75  60  55  75             
005    75  60  55  75             
006    75  60  55  75             
007    75  60  55  75             
008    75  60  55  75             
009    75  60  55  75             
010    75  60  55  75             
011    75  60  55  75             
012    75  60  55  75             
013    75  60  55  75             
014    75  60  55  75             
015    75  60  55  75             
016    75  60  55  75             
017    80  70  60  80             
018    80  70  60  80             
019    80  70  60  80             
020    80  70  60  80             
021    80  70  60  80             
022    80  70  60  80             
Buildings Total 1800  1500  24  1335  1800                
Total Units : 6459 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 4
Existing Meters 3 + New Meters 2 - Removed Meters 0 = Total Meters 5

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/30/2017 Notice: 1 - FIRST NOTICE 06/24/2021
Power Issued: 03/30/2017 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  N/A

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M394085
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/25/2020 07/25/2020 ECH V (104) (9)
INSPECTION COMMENTS: FAIL, SERVICE INSPECTION COMPLETE, EVERYTHING ELSE NEEDS TO BE INSPECTED, NEW PERMIT REQUIRED FOR ALL MOTORS, HEATERS, AND TRANSFORMERS
 
(2) 08/01/2020 08/03/2020 ECH V X (224) (1)
INSPECTION COMMENTS: FAIL, INSPECTION COMPLETE, SEE OBJECTIONS
 
(3) 09/26/2020 09/28/2020 JRP N (15) (0) Y
INSPECTION COMMENTS: OFFICE CALLED CONTRACTOR NO ANSWER, SPOKE TO BUILDING ENGINEER DIDN'T KNOW OF INSPECTION SCHEDULE FOR TODAY. NO SHOW
 
(4) 10/04/2020 10/05/2020 MJD V Y (300) (10)
INSPECTION COMMENTS: FAIL, INSPECTION COMPLETE
 
(5) 06/23/2021 06/24/2021 MJD V Y (97) (1)
INSPECTION COMMENTS: FAIL, INSPECTION COMPLETE,
 
(6) 06/29/2021 06/29/2021 CLC J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-21-000022476
 
(7) 06/29/2021 06/29/2021 CLC J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-21-000022478
 
(8) 09/03/2021 09/03/2021 ASK H Y (34) (0)
INSPECTION COMMENTS: FAIL. INSPECTION COMPLETED. AS PER OFFICE T.SCHULER ONE OBJECTION REMAIN . SEE PICTURE ATTACHED IN EMAIL ON 09/03/21. ATOI MIKE.
 
(9) 11/01/2021 11/01/2021 SWR N (25) (0) Y
INSPECTION COMMENTS: CONTRACTOR SAID THAT HE HAS NO ACCESS. OFFICE DIRECTION OK TO PROCEED.
 
(10) 07/24/2022 07/25/2022 TUR C R (1) (0)
INSPECTION COMMENTS: OK TO CERTIFY ALL OBJECTIONS REMOVED

OBJECTION FOR APPLICATION #: M394085
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (221) NOT INSTALLED PER ADVISORY BOARD DRAWING
(FLOOR: 001)MDP ON 1ST FLOOR, BREAKERS DO NOT MATCH PRINT NYC AMENDMENT 110.2
RSLV 07/25/2020 07/25/2020 10/04/2020
 
002 (177) DESIGN AND/OR CONSTRUCTION DOES NOT MEET CODE REQUIREMENTS
(ALL FLOORS)NEW PERMIT REQUIRED FOR ALL MOTORS, HEATERS, AND TRANSFORMERS, NYCAMENDMENT 27-3018
RSLV 07/25/2020 07/25/2020 09/03/2021
 
003 (221) NOT INSTALLED PER ADVISORY BOARD DRAWING
(ALL FLOORS)FIRE PUMP, SIZE, HP, FUSE SIZE, AND WIRE COUNT DO NOT MATCH DRAWINGNYC AMENDMENT 110.2
RSLV 07/25/2020 07/25/2020 10/04/2020
 
004 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
(ALL FLOORS)KO'S MISSING FROM SWITCHES, PANELS, AND BOXES THROUGHOUT
RSLV 07/25/2020 07/25/2020 06/23/2021
 
005 (143) LUMINAIRES NOT PROPERLY SUPPORTED/SECURED
(CELLAR) EXIT SIGNS IN HALLWAY SUPPORTED BY EMT NEC 410.30
RSLV 07/25/2020 07/25/2020 10/04/2020
 
006 (221) NOT INSTALLED PER ADVISORY BOARD DRAWING
(CELLAR)FEED FROM END LINE BOX TO SERVICE B DOES NOT MATCH PRINT, NYCAMENDMENT 110.2
RSLV 07/25/2020 07/25/2020 10/04/2020
 
007 ( 7) EMT IS NOT PROPERLY SUPPORTED (TYPE:EMT)
(CELLAR) EMT NOT SUPPORTED THROUGHOUT NEC 358.30
RSLV 07/25/2020 07/25/2020 10/04/2020
 
008 (221) NOT INSTALLED PER ADVISORY BOARD DRAWING
(ROOF) MDP ON ROOF, BREAKERS DO NOT MATCH PRINT NYC AMENDMENT 110.2
RSLV 07/25/2020 07/25/2020 10/04/2020
 
009 (221) NOT INSTALLED PER ADVISORY BOARD DRAWING
(SUB-CELLAR) MDP-SC BREAKERS DO NOT MATCH PRINT NYC AMENDMENT 110.2
RSLV 07/25/2020 07/25/2020 10/04/2020
 
010 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
(ALL FLOORS)AFCI PROTECTION REQUIRED IN HALLWAYS OF ALL UNITS NEC 210.12
RSLV 08/01/2020 08/01/2020 10/04/2020
 
011 ( 14) CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE
(ALL FLOORS)ART. 110.3 ALL 15 AMP RATED AIR HANDLERS OVER FUSED AS PERMANUFACTORY SPECIFICATION REQUIREMENTS, ALL UNITS
RSLV 10/04/2020 10/04/2020 06/23/2021
 
012 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(ALL FLOORS) ART. 110.12 BREAKERS FILLERS MISSING AL MDP PANELS
RSLV 10/04/2020 10/04/2020 06/23/2021
 
013 (181) DISCONNECTING MEANS IS IMPROPER/NOT PROVIDED
(ALL FLOORS)ART. 424.19 ALL UNITS BASEBOARD HEATERS DISCONNECTS NOT PROVIDED
RSLV 10/04/2020 10/04/2020 06/23/2021
 
014 ( 25) ARMORED CABLES ARE NOT PROPERLY TERMINATED
(ALL FLOORS)ART. 110.3 AP CABLES NOT TERMINATED AS PER MANUFACTORY REQUIREMENTSALL PANELS ALL UNITS
RSLV 10/04/2020 10/04/2020 06/23/2021
 
015 (272) EQUIPMENT GROUNDING CONDUCTOR NOT PROPERLY INSTALLED
(ALL FLOORS)ART. 250.118, 250.148 MC CABLE GROUND CONDUCTOR NOT LANDED ON BOXESWHERE USED, ALL UNITS DRYER RECEPTACLES
RSLV 10/04/2020 10/04/2020 06/23/2021
 
016 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
(ALL FLOORS)ART. 210.52 ALL UNITS WHERE ISLAND/PENINSULAS INSTALLED SERVING ASROOM DIVIDERS ROOM SIDE RECEPTACLES NOT PROVIDED
RSLV 10/04/2020 10/04/2020 07/24/2022
 
017 (999) OTHER
(ALL FLOORS)CONTRACTOR LIKE TO UPLOAD AFFIDAVIT FOR ALL UNITS ELECTRICAL STOVES,CONTRACTOR IS NOT ABLE TO PULL THEM OUT FOR CONNECTION INSPECTION
RSLV 10/04/2020 10/04/2020 06/29/2021
 
018 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(BASEMENT) AM. 230.70 SERVICE DISCONNECTS NOT IDENTIFIED
RSLV 10/04/2020 10/04/2020 06/23/2021
 
019 (269) FIRE PUMP SUPPLY CONDUCTORS NOT PROPERLY INSTALLED
(CELLAR) AM. 695.6 EMT USED BETWEEN PUMP AND CONTROLLER
RSLV 10/04/2020 10/04/2020 06/23/2021
 
020 (109) SUFFICIENT WORK SPACE IS NOT PROVIDED/MAINTAINED
(ROOF)ART. 110.26 ROOF ELECTRICAL ROOM WITH 1200 AMP MDP INSTALLED PANICHARDWARE NOT PROVIDED ON EXIT DOOR
RSLV 10/04/2020 10/04/2020 06/23/2021
 
021 (999) OTHER
(ALL FLOORS)CONTRACTOR LIKE TO UPLOAD AFFIDAVIT FOR ALL DRYER RECEPTACLES, ALLAPARTMENTS
RSLV 06/23/2021 06/23/2021 06/29/2021