| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
5 |
20 CIRCUITS |
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(282) |
MINIMUM NUMBER OF SMALL APPLIANCE CIRCUITS (FLOOR: 001) ONLY ONE CKT IN KITCHEN COUNTER 210.52 |
RSLV |
03/22/2018 |
03/22/2018 |
05/16/2018 |
| |
| 002 |
(211) |
RECEPTACLE IS NOT PROPERLY BONDED/GROUNDED (ALL FLOORS) OUTLETS NOT GROUNDED T OUT 250.146 |
RSLV |
03/22/2018 |
03/22/2018 |
05/16/2018 |
| |
| 003 |
( 22) |
FIXED EQUIPMENT IS NOT PROPERLY GROUNDED (ALL FLOORS) NO CHANGE OVER FOR ALL 1/2 PIPE WITH 1900 BOXES 250.8 |
RSLV |
03/22/2018 |
03/22/2018 |
05/16/2018 |
| |
| 004 |
( 22) |
FIXED EQUIPMENT IS NOT PROPERLY GROUNDED (ALL FLOORS) ALL MC CABLE NOT BONDED TO BOX 250.148 |
RSLV |
03/22/2018 |
03/22/2018 |
05/16/2018 |
| |
| 005 |
(340) |
RECEPTACLES NOT TAMPERPROOF (ALL FLOORS) KITCHEN COUNTER 406.11 |
RSLV |
03/22/2018 |
03/22/2018 |
05/16/2018 |
| |
| 006 |
( 46) |
PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY (ALL FLOORS) NO DIRECTORY ALL APTS |
RSLV |
03/22/2018 |
03/22/2018 |
05/16/2018 |
| |
| 007 |
( 53) |
GFCI HAS NOT BEEN PROVIDED (ALL FLOORS) NO GFCI PROTECTION ON KITCHEN COUNTER 210.8 |
RSLV |
03/22/2018 |
03/22/2018 |
05/16/2018 |
| |
| 008 |
(999) |
OTHER (ALL FLOORS) SHEET ROCK SCREWS FOR OUTLETS 110.3 |
RSLV |
03/22/2018 |
03/22/2018 |
05/16/2018 |
| |
| 009 |
(999) |
OTHER (ALL FLOORS) NO 120V LAUNDRY CKT PROVIDED FOR LAUNDRY AREA 210.11 |
RSLV |
03/22/2018 |
03/22/2018 |
07/20/2018 |