BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M388894
Premises: 244 7 AVENUE MANHATTAN BIN: 1014176     Block: 774   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 252 7 AV Census Tract:   91 Health Area:  5200
10R Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10001 Community Board:   104
DOB Cross Street(s):   WEST 24 STREET,    WEST 25 STREET
Status:   C - JOB IS SIGNED OFF 12/27/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/11/2016 5:18 PM
Application Entered:   11/11/2016 Job Start Date:   11/12/2016
Last Change:   12/27/2017 Job End Date:   11/12/2017
Appointment Status:   
Last Inspection By:   ROBINSON HEATH       On     10/20/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011693 Licensee Name: EVANGELINA APRILAKIS
Firm: 004165 Firm Name: EUROPA ELECTRIC OF NY COR
Firm Phone: 718-661-2660  Firm Address: 18-41 STEINWAY STREET ASTORIA NY 11105 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $60.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: BRETT KLEIN
Owner Business Name: N/A
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  5 CKTS 100 AMP
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
010  10R  10    10             
Buildings Total 10    10                
Total Units : 30 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 09/08/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  N/A

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M388894
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/19/2017 06/20/2017 STP V (30) (6)
INSPECTION COMMENTS: FAIL. CONTRACTOR STATED EXISTING CIRCUITS.
 
(2) 08/17/2017 08/17/2017 TOR N (21) (0) Y
INSPECTION COMMENTS: CALLED CONTRACTOR NO SHOW
 
(3) 09/08/2017 09/08/2017 EDB V Y (45) (1)
INSPECTION COMMENTS: SEE ATTACHMENT.
 
(4) 10/11/2017 10/11/2017 ATH J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-17-000013282
 
(5) 10/20/2017 10/23/2017 HRB C R (20) (0)
INSPECTION COMMENTS: PASSED

OBJECTION FOR APPLICATION #: M388894
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 010) KITCHEN COUNTER NEEDS RECEPTACLE 210.52
RSLV 06/19/2017 06/19/2017 09/08/2017
 
002 (999) OTHER
(FLOOR: 010) NO WORK SPACE FOR PANEL 110.26
RSLV 06/19/2017 06/19/2017 09/08/2017
 
003 (999) OTHER
(FLOOR: 010) BOX EXTENDERS FOR KITCHEN RECEPTACLE 314.20
RSLV 06/19/2017 06/19/2017 10/20/2017
 
004 (999) OTHER
(FLOOR: 010) KO OPEN IN PANEL 110.12
RSLV 06/19/2017 06/19/2017 09/08/2017
 
005 (999) OTHER
(FLOOR: 010) NEUTRAL DOUBLE LUGG PANEL 110.14
RSLV 06/19/2017 06/19/2017 09/08/2017
 
006 (999) OTHER
(FLOOR: 010) HANDLE TIES NEEDED MULTI CKTS 210.4
RSLV 06/19/2017 06/19/2017 10/20/2017
 
007 (296) PANEL IS LOCATED IN CLOTHES/LINEN CLOSET
(FLOOR: 010)PANEL IN CLOTHE CLOSET 210.10(D),240.24(D)
RSLV 09/08/2017 09/08/2017 10/11/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.