Electrical Application Details for App #: M387826
Premises: 214 WEST 24 STREET MANHATTAN BIN: 1014159     Block: 773   Lot: 56
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 220 W. 24TH ST Census Tract:   91 Health Area:  5200
APTS. 2A & 5B Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10011 Community Board:   104
DOB Cross Street(s):    7 AVENUE,    8 AVENUE
Status:   C - JOB IS SIGNED OFF 08/25/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/15/2016 9:45 AM
Application Entered:   10/15/2016 Job Start Date:   10/15/2016
Last Change:   08/25/2017 Job End Date:   02/15/2017
Appointment Status:   
Last Inspection By:   RACEWICZ, TOMASZ       On     07/13/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012024 Licensee Name: TIMOTHY COLEMAN
Firm: 003668 Firm Name: TIMOTHY COLEMAN LICENSED
Firm Phone: 718-337-0921  Firm Address: 19-14 MOTT AVENUE ELECTRICIAN FAR ROCKAWAY NY 11691 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $109.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: RENE PUMA
Owner Business Name: CL/WC OPERATION
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  3 - #6 AWG
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  ML 8/16 CKT 60 AMP
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002  2A    12             
005  5B    12             
Buildings Total   24  10  10                
Total Units : 46 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 04/03/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  GENERAL WIRING INCLUDING 1 DISHWASHER CIRCUIT EACH APARTMENT AND 1 COMBO SMOKE DETECTOR EACH APARTMENT

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M387826
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/24/2017 02/24/2017 CBK V (45) (3)
INSPECTION COMMENTS: SEE OBJECTION DETAILS.
 
(2) 03/31/2017 04/03/2017 STP V R (60) (2)
INSPECTION COMMENTS: FAIL. KITCHEN LED TRANSFORMER UNDER SINK TOUT.
 
(3) 07/13/2017 07/14/2017 TOR C R (30) (0)
INSPECTION COMMENTS: PASS

OBJECTION FOR APPLICATION #: M387826
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (211) RECEPTACLE IS NOT PROPERLY BONDED/GROUNDED
(FLOOR: 002) RECEPTACLES IN CABINET NOT PROPERLY BONDED.
RSLV 02/24/2017 02/24/2017 03/31/2017
 
002 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
(FLOOR: 002) AFCI NOT PROVIDED FOR SMOKE DETECTOR.
RSLV 02/24/2017 02/24/2017 03/31/2017
 
003 (999) OTHER
(ALL FLOORS) RECEPTACLE BOXES SET BACK IN CABINET.
RSLV 02/24/2017 02/24/2017 03/31/2017
 
004 ( 19) DEFECTIVE WIRING IS IN USE
(ALL FLOORS) LED XFMR TERMINATIONS EXPOSED NO BOX 300.15
RSLV 03/31/2017 03/31/2017 07/13/2017
 
005 (999) OTHER
(ALL FLOORS) LED XFMR NOT LISTED 110.3
RSLV 03/31/2017 03/31/2017 07/13/2017