Electrical Application Details for App #: M387300
Premises: 61 EAST END AVENUE MANHATTAN BIN: 1051382     Block: 1590   Lot: 8
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 75 E END AV Census Tract:   136 Health Area:  3800
APT. 2E Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10028 Community Board:   108
DOB Cross Street(s):   EAST 82 STREET,    EAST 83 STREET
Status:   C - JOB IS SIGNED OFF 12/27/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/03/2016 9:12 PM
Application Entered:   10/03/2016 Job Start Date:   10/03/2016
Last Change:   12/27/2017 Job End Date:   10/02/2017
Appointment Status:   
Last Inspection By:   ALBERT HANSON       On     10/24/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011762 Licensee Name: RABINDRA N RAMGARIB
Firm: 003374 Firm Name: INDY ELECTRIC CORP.
Firm Phone: 718-323-4639  Firm Address: 120-21 101 AVENUE RICHMOND HILL NY 11419 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $124.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: DAVID KAMP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  100 AMP MB
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002  60  60    10  60         
007  7E                       
Buildings Total 60  60    10  60              
Total Units : 197 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 08/23/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  N/A

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M387300
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/26/2017 07/26/2017 PHG V (40) (7)
INSPECTION COMMENTS: CONTRACTOR TO FIX APP TO REFLECT WORK DONE FEEDER SWITCHES MOTORS ECT. DID NOT SEE LED DRIVERS
 
(2) 08/23/2017 08/23/2017 MQY V R (38) (1)
INSPECTION COMMENTS: NEEDS 2 SHOWER TRIMS IN THE GUEST BATHROOM
 
(3) 10/24/2017 10/24/2017 ATH C R (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-17-000013970

OBJECTION FOR APPLICATION #: M387300
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
(FLOOR: 002) KITCHEN PLUG STRIP WIRED IN REVERSE 110.3
RSLV 07/26/2017 07/26/2017 08/23/2017
 
002 ( 28) ELECTRICAL MATERIAL USED FOR LUMINAIRES HAS NOT BEEN APPROVED
(FLOOR: 002) SHOWER TRIM PENDING APPROVAL 110.3
RSLV 07/26/2017 07/26/2017 08/23/2017
 
003 ( 45) FIXTURE NOT INSTALLED IN AN APPROVED MANNER
(FLOOR: 002) EXPOSED BULB IN CLOTHES CLOSET 410.16
RSLV 07/26/2017 07/26/2017 08/23/2017
 
004 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
(FLOOR: 002)NEW POWER BLOCK INSTALLED IN OLD BACK BOX 314.28 110.3 376.56
RSLV 07/26/2017 07/26/2017 08/23/2017
 
005 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
(FLOOR: 002) AFCI NOT PROVIDED IN NEEDED AREAS 210.12
RSLV 07/26/2017 07/26/2017 08/23/2017
 
006 (999) OTHER
(FLOOR: 002) FACE UP OUTLET IN BED ROOM 406.5
RSLV 07/26/2017 07/26/2017 08/23/2017
 
007 (999) OTHER
(FLOOR: 002)LOAD CALCULATION NEEDED FOR NEW 100 AMP LINE(ALL TENETS HAVE 40AMPS) 220.40
RSLV 07/26/2017 07/26/2017 08/23/2017
 
008 (999) OTHER
(FLOOR: 002) NEEDS 2 SHOWER TRIMS IN THE GUEST BATHROOM
RSLV 08/23/2017 08/23/2017 10/24/2017