Electrical Application Details for App #: M386858
Premises: 1493 BROADWAY MANHATTAN BIN: 1024706     Block: 1015   Lot: 29
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 1501 BROADWAY Census Tract:   119 Health Area:  5200
10TH FLOOR Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10036 Community Board:   105
DOB Cross Street(s):   WEST 43 STREET,    WEST 44 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/21/2016 6:25 PM
Application Entered:   09/21/2016 Job Start Date:   09/21/2016
Last Change:   08/22/2025 Job End Date:   10/21/2016
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   CONROY BLAKE       On     08/08/2018      
Field Disp:   J - JOB IN PROGRESS
Energize Recommendation:  
Objection Disposition:  

License #: 010626 Licensee Name: NEIL KORMAN
Firm: 000042 Firm Name: A.S.M. ELEC AND MACH CORP
Firm Phone: 212-695-0498  Firm Address: 333 WEST 39TH STREET ROOM 201 NEW YORK NY 10018 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $277.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: PARAMOUNT LEASEHOLD LP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  3  4 #3/0 WIRES
D. 3 Phase Over 225 AMPS  1  3 #500
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
010      10         
011      10         
Buildings Total 14    14     20           
Total Units : 58 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  RELOCATE AND INSTALL NEW PANEL BOXES ON EXISTING RISERS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M386858
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/08/2018 08/08/2018 CBK J (45) (0) Y
INSPECTION COMMENTS: JOB NOT READ FOR INSPECTION.