BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M385859
Premises: 221 WEST 23 STREET MANHATTAN BIN: 1014148     Block: 773   Lot: 27
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 225 W 23 ST Census Tract:   91 Health Area:  5200
4TH FLOOR APT 4A Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10011 Community Board:   104
DOB Cross Street(s):    7 AVENUE,    8 AVENUE
Status:   C - JOB IS SIGNED OFF 11/09/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/28/2016 11:19 AM
Application Entered:   08/28/2016 Job Start Date:   08/28/2016
Last Change:   11/09/2016 Job End Date:   08/27/2017
Appointment Status:   
Last Inspection By:   JOFFRE PENA       On     11/07/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012089 Licensee Name: PEDRO M ABREU
Firm: 004413 Firm Name: JAMCOB ELECTRIC LLC
Firm Phone: 347-577-6644  Firm Address: 1420 WHITE PLAINS ROAD BRONX NY 10462 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $57.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: RENA PUMA
Owner Business Name: THE PUMA HOME
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  UP TO 20
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
004  4A  12               
Buildings Total 12                  
Total Units : 20 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 10/25/2016
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALL NEW OUTLETS, LIGHT SWITCHES, AND BREAKER PANEL AT 4FLOOR APT 4A

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M385859
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/24/2016 10/25/2016 STP V (30) (3)
INSPECTION COMMENTS: FAIL.
 
(2) 11/07/2016 11/09/2016 JRP C R (40) (0)
INSPECTION COMMENTS: OBJECTIONS REMOVED, JOB COMPLETE

OBJECTION FOR APPLICATION #: M385859
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 004) SPLICE BOX FOR FEED BURIED 314.29
RSLV 10/24/2016 10/24/2016 11/07/2016
 
002 (999) OTHER
(FLOOR: 004) NO GFI 6FT SINK 210.8
RSLV 10/24/2016 10/24/2016 11/07/2016
 
003 (999) OTHER
(FLOOR: 004) NO TR RECEPTACLES TOUT 406.11
RSLV 10/24/2016 10/24/2016 11/07/2016



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.