BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M385296
Premises: 2 TUDOR CITY PLACE MANHATTAN BIN: 1038646     Block: 1333   Lot: 18
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 2 TUDOR CITY PL Census Tract:   88 Health Area:  5000
APT 9GN Admin Area:   M - MANHATTAN Inspection Area:   M
NEW YORK, NY 10017 Community Board:   106
DOB Cross Street(s):   DEAD END,    EAST 41 STREET
Status:   C - JOB IS SIGNED OFF 03/01/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/12/2016 5:14 PM
Application Entered:   08/12/2016 Job Start Date:   08/12/2016
Last Change:   03/01/2017 Job End Date:   08/17/2017
Appointment Status:   
Last Inspection By:   TREJO, JORGE       On     02/28/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012516 Licensee Name: ANA DIAZ
Firm: 004331 Firm Name: DIAZ ELECTRIC OF NEW YORK
Firm Phone: 800-605-7620  Firm Address: 220 36TH ST #B538BOX 29 INC BROOKLYN NY 11232 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $43.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: RICHARD MCMULLANE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
009      14               
Buildings Total   14                  
Total Units : 22 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: C - CALL TO OFFICE 02/13/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  ELECTRICAL CONTRACTOR WILL RUN NEW LINE FOR OUTDOOR AC UNIT. AND NEW OUTLETS FOR KITCHEN

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M385296
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/17/2017 01/17/2017 CBK V (45) (5)
INSPECTION COMMENTS: SEE OBJECTION DETAILS.
 
(2) 02/10/2017 02/13/2017 BUR H X (20) (0) Y
INSPECTION COMMENTS: CONTRACTOR NEED TO BE PRESENT TO CONDUCT INSPECTION
 
(3) 02/28/2017 03/01/2017 JTE C R (25) (0)
INSPECTION COMMENTS: INSPECTION PASSED, OBJECTION REMOVED.

OBJECTION FOR APPLICATION #: M385296
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (128) NEUTRAL IS GROUNDED BEYOND LOAD SIDE OF SERVICE SWITCH
(FLOOR: 009) NEUTRAL BONDED IN SPLICE BOX ABOVE OVEN.
RSLV 01/17/2017 01/17/2017 02/28/2017
 
002 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
(FLOOR: 009) BREAKER BLANKS MISSING.
RSLV 01/17/2017 01/17/2017 02/28/2017
 
003 ( 45) FIXTURE NOT INSTALLED IN AN APPROVED MANNER
(FLOOR: 009) KITCHEN LIGHT FIXTURE FOR KITCHEN NOT LISTED.
RSLV 01/17/2017 01/17/2017 02/28/2017
 
004 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
(FLOOR: 009)FRONT CLOSETS LIGHTS AND RECEPTACLES NOT AFCI PROTECTED.
RSLV 01/17/2017 01/17/2017 02/28/2017
 
005 (999) OTHER
(FLOOR: 009)KITCHEN RECEPTACLE BOXES SET BACK MORE THAN 1/4". 314.20
RSLV 01/17/2017 01/17/2017 02/28/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back