BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M380359
Premises: 254 EAST 68 STREET MANHATTAN BIN: 1043884     Block: 1422   Lot: 21
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 254 E 68TH ST Census Tract:   118 Health Area:  4400
1P30306 Admin Area:   M - MANHATTAN Inspection Area:   K
NEW YORK, NY 10065 Community Board:   108
Special Place Name:   ELEVATOR
DOB Cross Street(s):    3 AVENUE,    2 AVENUE
Status:   C - JOB IS SIGNED OFF 10/11/2022
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/13/2016 10:04 AM
Application Entered:   04/13/2016 Job Start Date:   05/21/2016
Last Change:   10/11/2022 Job End Date:   05/20/2017
Appointment Status:   
Last Inspection By:   RACEWICZ, TOMASZ       On     09/22/2022      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 012689 Licensee Name: JOSEPH F TRAPANI
Firm: 002610 Firm Name: P.S. MARCATO ELEV. CO INC
Firm Phone: 718-392-6400  Firm Address: 44-11 ELEVENTH STREET L.I.C. NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
Total Fee:  $414.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: RUDIN MANAGEMENT
Authorized Representative:  WILLIAM EXNER
Relationship To Owner:   AGENT


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  1  $125.00
B. Each Additional 10 Floors Or Less  3  $249.00
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  CONTROLS, HOIST MOTOR, BRAKE, DOOR OPERATOR, GATE SWITCH, LIMITS, TRAVELING CABLES, HOIST WAY WIRING, CAR WIRING, CAB FIXTURES, HALL FIXTURES, ELECTRONIC LEVELING SYSTEM, PIT LIGHTING, STOP SWITCH, MOTOR ROOM LIGHTING, TOP OF CAR INSPECTION STATION, OVER HEAD LIGHTING, SWITCH, STOP SWITCH, INTERCOM

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M380359
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/22/2022 09/22/2022 TOR C (45) (0) Y
INSPECTION COMMENTS: PASS




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back