Electrical Application Details for App #: M379613
Premises: 1302 1 AVENUE MANHATTAN BIN: 1045808     Block: 1465   Lot: 1
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 1310 1ST AV Census Tract:   124 Health Area:  4300
GROUND FLOOR Admin Area:   M - MANHATTAN Inspection Area:   K
NEW YORK, NY 10021 Community Board:   108
DOB Cross Street(s):   EAST 70 STREET,    EAST 71 STREET
Status:   C - JOB IS SIGNED OFF 08/24/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/25/2016 8:43 AM
Application Entered:   03/25/2016 Job Start Date:   03/25/2016
Last Change:   08/24/2017 Job End Date:   10/24/2016
Appointment Status:   
Last Inspection By:   GANITIS, PHILLIP       On     10/03/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012024 Licensee Name: TIMOTHY COLEMAN
Firm: 003668 Firm Name: TIMOTHY COLEMAN LICENSED
Firm Phone: 718-337-0921  Firm Address: 19-14 MOTT AVENUE ELECTRICIAN FAR ROCKAWAY NY 11691 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $119.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   K - Store
Store / Other:   ICE CREAM
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOSEPH IKHALEA
Owner Business Name: TASTI ON FIRST INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  1  3 PHASE #2AWG SUBFEEDER
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  24 CKTS 3 PHASE
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND      43      16             
Buildings Total   43      16                
Total Units : 59 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: C - CALL TO OFFICE 09/13/2016
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  GENERAL WIRING ONLY

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M379613
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/16/2016 06/16/2016 STP N (30) (0) Y
INSPECTION COMMENTS: NO SHOW CALLED CONTRACTOR NO ANSWER .
 
(2) 08/11/2016 08/12/2016 MQY V (23) (2)
INSPECTION COMMENTS: LIGHT FIXTURES ARE BEING SUPPORTED BY DROP CEILING WITHOUT ANY OTHER MEANS OF SUPPORTS. DROP CEILING IS BEING SUPPORTED BY INTERNAL WATER PIPES.
 
(3) 09/12/2016 09/13/2016 MQY H X (102) (0) Y
INSPECTION COMMENTS: NO PROGRESS
 
(4) 10/03/2016 10/04/2016 PHG C R (20) (0)
INSPECTION COMMENTS: P

OBJECTION FOR APPLICATION #: M379613
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(GROUND FLOOR) EXISTING PANEL BEING USED AS A RACEWAY (312.8)
RSLV 08/11/2016 08/11/2016 10/03/2016
 
002 (999) OTHER
(GROUND FLOOR)LIGHT FIXTURES NOT SUPPORTED PROPERLY ON SUPPORTED CEILING (410.36)
RSLV 08/11/2016 08/11/2016 10/03/2016



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order