BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M379063
Premises: 496 6 AVENUE MANHATTAN BIN: 1009610     Block: 576   Lot: 6
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 496 6 AV Census Tract:   63 Health Area:  5700
GROUND FLOOR Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10011 Community Board:   102
DOB Cross Street(s):   WEST 12 STREET,    WEST 13 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/12/2016 6:10 PM
Application Entered:   03/12/2016 Job Start Date:   03/14/2016
Last Change:   08/22/2025 Job End Date:   06/14/2016
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   CONROY BLAKE       On     07/05/2017      
Field Disp:   J - JOB IN PROGRESS
Energize Recommendation:  
Objection Disposition:  Y - PARTLY REMOVED

License #: 012702 Licensee Name: ALLAN TANG
Firm: 004539 Firm Name: A ELECTRICAL MAIN SVC INC
Firm Phone: 718-234-9250  Firm Address: 198 AVENUE S, 1ST FLOOR BROOKLYN NY 11223 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $111.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   K - Store
Store / Other:   JAPANESE RESTAURANT
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JAMES T KIM
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  1
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND      50    20  25           
Buildings Total   50    20  25              
Total Units : 96 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: C - CALL TO OFFICE 12/08/2016
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  PARTIAL WIRING AT GROUND FLOOR. EXISTING FEEDER AND PANEL.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M379063
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/28/2016 06/28/2016 UMS V (40) (5)
INSPECTION COMMENTS: SEE OBJECTIONS
 
(2) 09/14/2016 10/17/2016 STP N (20) (0) Y
INSPECTION COMMENTS: NO SHOW
 
(3) 12/06/2016 12/08/2016 MQY H X (96) (0) Y
INSPECTION COMMENTS: NO PROGRESS
 
(4) 07/05/2017 07/06/2017 CBK J Y (45) (0)
INSPECTION COMMENTS: OBJECTION PARTIALLY REMOVED.

OBJECTION FOR APPLICATION #: M379063
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(BASEMENT)NO WORKING SPACE PROVIDED FOR OUTDOOR UNIT DISCONNECT SWITCH. NEC110.26
RSLV 06/28/2016 06/28/2016 07/05/2017
 
002 (999) OTHER
(BASEMENT)NO DISCONNECT SWITCHES PROVIDED FOR WALK IN FREEZER MOTORS. NEC 440
OPEN 06/28/2016 06/28/2016
 
003 (999) OTHER
(BASEMENT)SERVICE RECEPTACLE OUTLET BY OUTDOOR A/C UNIT NOT PROVIDED. NEC210.63
OPEN 06/28/2016 06/28/2016
 
004 (999) OTHER
(GROUND FLOOR)NO HANDLE TIES USED FOR MULTIWIRE BRANCH CIRCUITS, NEC 210.4
OPEN 06/28/2016 06/28/2016
 
005 (999) OTHER
(GROUND FLOOR)NO GFI PROTECTION PROVIDED FOR KITCHEN 110 VOLT RECEPTACLES. NEC210.8
RSLV 06/28/2016 06/28/2016 07/05/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order