BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M375524
Premises: 1534 3 AVENUE MANHATTAN BIN: 1047963     Block: 1515   Lot: 35
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 1534 3RD AV Census Tract:   148.02 Health Area:  3600
1ST 2ND Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10028 Community Board:   108
DOB Cross Street(s):   EAST 86 STREET,    EAST 87 STREET
Status:   C - JOB IS SIGNED OFF 01/27/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/04/2015 7:14 AM
Application Entered:   12/04/2015 Job Start Date:   12/04/2015
Last Change:   01/27/2016 Job End Date:   12/31/2015
Appointment Status:   
Last Inspection By:   SOLAVNTO, THOMAS       On     01/20/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011467 Licensee Name: KENNETH FISK
Firm: 003987 Firm Name: KENNETH FISK ELECTRIC COR
Firm Phone: 718-326-2378  Firm Address: 72-02 COOPER AVENUE GLENDALE NY 11385 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $40.00
Other Work:   REMOVE VIOLATIONS
Violations To Be Removed That Were Issued To Or Filed By Another Licensed Firm:     M313215         
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   K - Store
Store / Other:   RESTAURANT
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: HOWARD MCGEE
Owner Business Name: RECESS RESTAURANT
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001                   
Buildings Total                   
Total Units : 3 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REMOVE OBJECTIONS NOTED ON M313215 (WORK DONE BY ORIGINAL CONTRACTOR).

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M375524
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/14/2015 12/15/2015 EID J (41) (0) Y
INSPECTION COMMENTS: CONTRACTOR FILED NEW APP. TO REMOVE OBJECTIONS ON EXISTING/OLD APP. NEEDS TO SCHEDULE APPOINTMENT FOR BOTH APPS FOR INSPECTION.
 
(2) 01/14/2016 01/14/2016 NRS J (15) (0) Y
INSPECTION COMMENTS: JOB IN PROGRESS - SEE NOTES ON ORIGINAL APPLICATION (M313215). (JOB INSPECTED ON THE 7TH OF JAN., DID NOT GO THROUGH)
 
(3) 01/20/2016 01/20/2016 TSO C (1) (0) Y
INSPECTION COMMENTS: CERTIFIED IN OFFICE.




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.