Electrical Application Details for App #: M375467
Premises: 236 WEST 26 STREET MANHATTAN BIN: 1014205     Block: 775   Lot: 60
   

DOB NOW: Inspections


Filed: 236 W 26 ST Census Tract:   91 Health Area:  5200
9 FL. APT. # 903-905 Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10001 Community Board:   104
DOB Cross Street(s):    7 AVENUE,    8 AVENUE
Status:   C - SIGNOFF IS AWAITING FEE PAYMENT 04/26/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/02/2015 8:58 PM
Application Entered:   12/02/2015 Job Start Date:   12/05/2015
Last Change:   04/26/2018 Job End Date:   10/30/2016
Appointment Status:   
Last Inspection By:   ROBINSON HEATH       On     04/26/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010450 Licensee Name: JOHN REY
Firm: 001590 Firm Name: J&R REY ELEC. CONTR. INC.
Firm Phone: 212-684-2559  Firm Address: 3471 STEENWICK AVENUE BRONX NY 10475 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $181.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (1  Stores, 27 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: BILL WHITE
Owner Business Name: RESIDENTIAL
Authorized Representative:  VICTOR MINOVSKI
Relationship To Owner:   CONTR.


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
009  903-5  70  60  30    12         
Buildings Total 70  60  30       12           
Total Units : 175 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 04/12/2018
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  NEW WIRING

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M375467
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/12/2018 04/12/2018 TOR V (45) (4)
INSPECTION COMMENTS: FAIL
 
(2) 04/26/2018 04/26/2018 HRB C R (75) (0)
INSPECTION COMMENTS: PASSED

OBJECTION FOR APPLICATION #: M375467
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 53) GFCI HAS NOT BEEN PROVIDED
(ALL FLOORS) KITCHEN PENINSULA T-OUT
RSLV 04/12/2018 04/12/2018 04/26/2018
 
002 (999) OTHER
(ALL FLOORS) RECEPTACLES SET BACK IN WOOD 314.20 T-OUT
RSLV 04/12/2018 04/12/2018 04/26/2018
 
003 (999) OTHER
(ALL FLOORS) KITCHEN PENINSULA RECEPTACLES NOT TR TYPE 406.11
RSLV 04/12/2018 04/12/2018 04/26/2018
 
004 ( 19) DEFECTIVE WIRING IS IN USE
(ROOF) RECEPTACLE NOT WR RATED BY THE COMPRESSOR
RSLV 04/12/2018 04/12/2018 04/26/2018