BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M375067
Premises: 743 BROADWAY MANHATTAN BIN: 1080855     Block: 548   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 60 E 8 ST Census Tract:   57 Health Area:  5700
BASEMENT Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10003 Community Board:   102
DOB Cross Street(s):   MERCER STREET,    BROADWAY
Status:   C - JOB IS SIGNED OFF 02/05/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/19/2015 4:25 AM
Application Entered:   11/19/2015 Job Start Date:   11/25/2015
Last Change:   02/05/2016 Job End Date:   03/15/2016
Appointment Status:   
Last Inspection By:   RAMJAG, BUDRAM       On     12/08/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010843 Licensee Name: LENNOX NELSON
Firm: 002712 Firm Name: LENLITE ELEC'L CONTR'S IN
Firm Phone: 718-658-6732  Firm Address: 420 NEW JERSEY AVENUE BROOKLYN NY 11207 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $47.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: GERALD SOLOWAY
Owner Business Name: GEORGETOWN PLAZA OWNERS C
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS              40         
Buildings Total              40           
Total Units : 40 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REPLACING MOTOR STARTER WITH VFD CONTROL

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M375067
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/08/2015 12/08/2015 BUR C (70) (0) Y
INSPECTION COMMENTS: ELECTRICIAN STATED OLD MOTOR STARTER REMOVED AND NEW VARIABLE SPEED DRIVE INSTALLED IN BASEMENT




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order