BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M370896
Premises: 130 EAST 75 STREET MANHATTAN BIN: 1076301     Block: 1409   Lot: 7502
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 130 E 75 ST Census Tract:   128 Health Area:  4100
APT 8-B Admin Area:   M - MANHATTAN Inspection Area:   K
NEW YORK, NY 10021 Community Board:   108
DOB Cross Street(s):   PARK AVENUE,    LEXINGTON AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/06/2015 2:40 PM
Application Entered:   08/06/2015 Job Start Date:   08/12/2015
Last Change:   08/22/2025 Job End Date:   12/12/2015
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   RAMJAG, BUDRAM       On     02/22/2016      
Field Disp:   V - OBJCTN ISSD: JOB INCOMPLT
Energize Recommendation:  
Objection Disposition:  

License #: 011286 Licensee Name: MICHAEL DISCENZA
Firm: 002688 Firm Name: SURE ELEC'L CONTR'G CORP.
Firm Phone: 718-227-2889  Firm Address: 360 TARGEE STREET STATEN ISLAND NY 10304 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $54.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: GINO CAPPOLINO
Owner Business Name: STRUCTURE-NY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
008  8-B  20  18    12  18             
Buildings Total 20  18    12  18                
Total Units : 68 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: 1 - FIRST NOTICE 02/22/2016
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  RENOVATION OF EXISTING CIRCUITS NEW LIGHTING IN KITCHEN AREA

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M370896
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/22/2016 02/22/2016 BUR V (20) (2)
INSPECTION COMMENTS: BRANCH WIRING, AIR CONDITIONING WORK NOT FILED ON APPLICATION

OBJECTION FOR APPLICATION #: M370896
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 008) DEVICE RECESS MORE THAN 1/4 INCH IN WALL 314.20
OPEN 02/22/2016 02/22/2016
 
002 (999) OTHER
(FLOOR: 008)MC CABLE NOT TERMINATED PROPERLY IN RECEPTACLE BOX 330.108
OPEN 02/22/2016 02/22/2016



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order