BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M369944
Premises: 40 CORNELIA STREET MANHATTAN BIN: 1010067     Block: 589   Lot: 10
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 255 BLEEKER ST Census Tract:   67 Health Area:  6400
BASEMEN/GROUND Admin Area:   M - MANHATTAN Inspection Area:   R
NEW YORK, NY 10014 Community Board:   102
DOB Cross Street(s):   LEROY STREET,    CORNELIA STREET
Status:   C - JOB IS SIGNED OFF 07/28/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/15/2015 12:50 AM
Application Entered:   07/15/2015 Job Start Date:   07/15/2015
Last Change:   07/28/2017 Job End Date:   10/13/2015
Appointment Status:   
Last Inspection By:   RAMJAG, BUDRAM       On     03/16/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012724 Licensee Name: JUAN C ASCUASIATI
Firm: 004563 Firm Name: ASCUATECH ELECTRICAL CORP
Firm Phone: 718-583-2519  Firm Address: 448 EAST 173RD STREET BRONX NY 10457 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $97.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   RESTAURANT
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: YARA WOLOS
Owner Business Name: LA CORNELIA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  150A 18CIRC. MLP
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS      13         
GND                 
Buildings Total 10    17              
Total Units : 40 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 02/16/2016
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  UPGRADE CIRCUIT BREAKER PANEL IN BASEMENT, INSTALL LIGHT FIXTURES AND NEW RECEPTACLE OUTLETS IN KITCHEN.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M369944
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/16/2016 02/16/2016 NRS V (51) (5)
INSPECTION COMMENTS: BASEMENT LIGHTS & BATHROOMS, GR. FL. EXIT SIGNS, KITCHEN LIGHTS & SOME RECEPTACLES.
 
(2) 03/16/2017 03/17/2017 BUR C R (25) (0)
INSPECTION COMMENTS: OBJECTION RESOLVED

OBJECTION FOR APPLICATION #: M369944
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (132) EQUIPMENT/MATERIAL IS NOT PROPERLY GROUNDED
(BASEMENT) OUTLET BOXES WITH MC CABLE 250.8
RSLV 02/16/2016 02/16/2016 03/16/2017
 
002 ( 40) LOCKNUTS ARE MISSING OR LOOSE
(BASEMENT) MISSING & LOOSE IN CEILING BOX IN OFFICE
RSLV 02/16/2016 02/16/2016 03/16/2017
 
003 (999) OTHER
(BASEMENT) OUTLET BOXES SET TOO DEEP IN WALL 314.20
RSLV 02/16/2016 02/16/2016 03/16/2017
 
004 ( 53) GFCI HAS NOT BEEN PROVIDED
(GROUND FLOOR) WITHIN 6' OF SINK
RSLV 02/16/2016 02/16/2016 03/16/2017
 
005 ( 53) GFCI HAS NOT BEEN PROVIDED
(GROUND FLOOR) WITHIN 6' OF SINK
RSLV 02/16/2016 02/16/2016 03/16/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.