BIS Menu  |  Applications  |  After Hours Variance Permits  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M369559
Premises: 12 EAST 88 STREET MANHATTAN BIN: 1046923     Block: 1499   Lot: 61
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 12 E 88 ST Census Tract:   150.02 Health Area:  3600
CEL, 1 13, ROOF Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10128 Community Board:   108
DOB Cross Street(s):    5 AVENUE,    MADISON AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/02/2015 6:11 PM
Application Entered:   07/02/2015 Job Start Date:   07/03/2015
Last Change:   08/22/2025 Job End Date:   11/25/2016
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   GANITIS, PHILLIP       On     09/12/2018      
Field Disp:   V - OBJCTN ISSD: JOB INCOMPLT
Energize Recommendation:  
Objection Disposition:  

License #: 010786 Licensee Name: JOE ZAGO
Firm: 004257 Firm Name: ROMA ELECTRIC CORP
Firm Phone: 718-777-7662  Firm Address: 30-75 14TH STREET ASTORIA NY 11102 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
T - TEMPORARY LIGHT & POWER
Total Fee:  $865.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MATTHEW M BARON
Owner Business Name: 12 EAST 88TH, LLC
Authorized Representative:  FENNELL BRENDAN
Relationship To Owner:   OWNERS REP


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL      52    18  84             
001      108    22  90             
002      106    20  82             
003      128    32  92  15         
004      106    28  86             
005      106    28  86             
006      124    30  88             
007      136    38  102             
008      118    24  80             
009      102    22  76             
010      148    34  112             
011      84    20  73             
012      72    16  64             
013      64    12  48             
ROF        48  320         
Buildings Total   1460    346  1169     335           
Total Units : 3310 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: 1 - FIRST NOTICE 09/12/2018
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  WIRING FOR POWER & LIGHTING FOR PARTIAL RENOVATED EXISTING APARTMENTS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M369559
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/12/2018 09/12/2018 PHG V (135) (18)
INSPECTION COMMENTS: CONTRACTOR TO AMEND APP TO REFLECT WORK. DEVICE COUNT T OUT NO MOTORS IN APTS ON FILE. INSPECTED BSMT ROOF AND SOME APTS DID NOT INSPECT PH 12 FLOOR HALF 11 FL 10 B 8 FL AND 7E. DID NOT INSPECT WORK BELOW 7 FLOOR EXCEPT FOR BSMT

OBJECTION FOR APPLICATION #: M369559
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (111) SUFFICIENT WORK SPACE IS NOT PROVIDED/MAINTAINED
(FLOOR: 006) NO WORKING SPACE PANEL IN CLOTHES CLOSET 110.26
OPEN 09/12/2018 09/12/2018
 
002 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(FLOOR: 006) HANGING LIVING ROOM LIGHT NO GROUND 250.122
OPEN 09/12/2018 09/12/2018
 
003 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(FLOOR: 007) PULL BOX 7 A MC CABLE NOT TERMINATED 250.8
OPEN 09/12/2018 09/12/2018
 
004 ( 16) DEFECTIVE LIGHTING FIXTURES ARE IN USE
(FLOOR: 008) EXPOSED BULB IN CLOTHES CLOSET 8 FL 410.16
OPEN 09/12/2018 09/12/2018
 
005 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(FLOOR: 009) MC CABLE NOT TERMINATED APT 9 D
OPEN 09/12/2018 09/12/2018
 
006 (229) SPLICE BOXES NOT ACCESSIBLE
(FLOOR: 009) BURIED BOX APT 9 A 314.29
OPEN 09/12/2018 09/12/2018
 
007 (283) SMALL APPLIANCE OUTLETS NOT PROPERLY LOCATED
(FLOOR: 011) IMPROPER KITCHEN PLACEMENT 11 FL 210.52
OPEN 09/12/2018 09/12/2018
 
008 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
(FLOOR: 011) NO OUTLET FOR ALL BALCONY 11 FL 210.63
OPEN 09/12/2018 09/12/2018
 
009 (128) NEUTRAL IS GROUNDED BEYOND LOAD SIDE OF SERVICE SWITCH
(ALL FLOORS) ALL PANELS NEUTRAL BONDED 250.24
OPEN 09/12/2018 09/12/2018
 
010 (229) SPLICE BOXES NOT ACCESSIBLE
(ALL FLOORS) ALL D LINE BURIED BOX NEXT TO CA 314.29
OPEN 09/12/2018 09/12/2018
 
011 ( 29) OUTLET BOXES ARE NOT COVERED
(ALL FLOORS) ALL AIR HANDIER DISCONNECT NOT COVERED
OPEN 09/12/2018 09/12/2018
 
012 (296) PANEL IS LOCATED IN CLOTHES/LINEN CLOSET
(ALL FLOORS) ALL D LINE PANEL IN CLOTHES CLOSET 240.24
OPEN 09/12/2018 09/12/2018
 
013 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
(ALL FLOORS) NO AFCI ON ALL 120 V LAUNDRY CKT 210.12
OPEN 09/12/2018 09/12/2018
 
014 (111) SUFFICIENT WORK SPACE IS NOT PROVIDED/MAINTAINED
(ROOF) NO WORKING SPACE FOR ALL AC DISCONNECTS
OPEN 09/12/2018 09/12/2018
 
015 ( 14) CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE
(ROOF) AC FOR APT 4C OVER FUSED 240.4
OPEN 09/12/2018 09/12/2018
 
016 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(ROOF) GROUNDS NOT TERMINATED ROOF PANEL 250.8
OPEN 09/12/2018 09/12/2018
 
017 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
(ROOF) NO OUTLETS 25 FT FROM UNIT BOTH LEVELS OF ROOF 210.63
OPEN 09/12/2018 09/12/2018
 
018 (999) OTHER
(ROOF) NO HANDLE TIES ROOF PANEL 210.4
OPEN 09/12/2018 09/12/2018