Electrical Application Details for App #: M361687
Premises: 1481 5 AVENUE MANHATTAN BIN: 1087768     Block: 1746   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 1481 5 AV Census Tract:   198 Health Area:  1600
1-4 Admin Area:   M - MANHATTAN Inspection Area:   H
NEW YORK, NY 10035 Community Board:   111
DOB Cross Street(s):    5 AVENUE,    MADISON AVENUE
Status:   C - JOB IS SIGNED OFF 01/25/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/10/2014 4:12 PM
Application Entered:   12/10/2014 Job Start Date:   12/11/2014
Last Change:   01/25/2018 Job End Date:   02/01/2016
Appointment Status:   
Last Inspection By:   GARY MCCALLA       On     11/20/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011442 Licensee Name: RICHARD A RICHARDSON
Firm: 003781 Firm Name: AWI ELECTRIC AND ENERGY
Firm Phone: 212-982-3406  Firm Address: 291 EAST 4TH STREET RESOURCES CORP NEW YORK NY 10009 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $1,791.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   CHURCH
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: BETHEL GOSPEL ASSEMBLY
Authorized Representative:  VINCENT WILLIAMS
Relationship To Owner:   TRUSTEE


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  8  
D. Over 250 MCM  3  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  8  
D. 3 Phase Over 225 AMPS  3  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001    270  70    40  270             
002    170  42    15  170             
003    250  27    20  250             
004    260  31    30  260             
Buildings Total 950  170    105  950                
Total Units : 2175 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 10/30/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M361687
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/27/2017 10/30/2017 PHG V (160) (9)
INSPECTION COMMENTS: DID NOT INSPECT POOL. POOL NOT READY FOR INSPECTION CONTRACTOR TO FIX APP REMOVE 3 PANELS OVER 225 AMP FILE FOR HEATERS AND AC WORK DID NOT SEE ISOLATED GROUND CONNECTION
 
(2) 11/20/2017 11/21/2017 GYM C R (45) (0)
INSPECTION COMMENTS: PASS

OBJECTION FOR APPLICATION #: M361687
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 001) OUTLETS 6 FT FROM POOL 680.34
RSLV 10/27/2017 10/27/2017 11/20/2017
 
002 (999) OTHER
(FLOOR: 001) PLASTIC SEAL TIGHT USED IN AV ROOM 356.10
RSLV 10/27/2017 10/27/2017 11/20/2017
 
003 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(FLOOR: 003) NO ECG FOR POWER PROCESSOR WITH 75 KVA XFRM 250.66
RSLV 10/27/2017 10/27/2017 11/20/2017
 
004 (999) OTHER
(FLOOR: 004) NO HANDLE TIES FOR PANEL SL4 210.4
RSLV 10/27/2017 10/27/2017 11/20/2017
 
005 (111) SUFFICIENT WORK SPACE IS NOT PROVIDED/MAINTAINED
(ALL FLOORS) NO WORKING SPACE ALL AC DISCONNECTS 110.26
RSLV 10/27/2017 10/27/2017 11/20/2017
 
006 ( 53) GFCI HAS NOT BEEN PROVIDED
(ALL FLOORS) NO GFCI IN WOMAN'S AND MENS RM
RSLV 10/27/2017 10/27/2017 11/20/2017
 
007 ( 53) GFCI HAS NOT BEEN PROVIDED
(ALL FLOORS) WATER FOUNTAIN NO GFCI PROVIDED T OUT
RSLV 10/27/2017 10/27/2017 11/20/2017
 
008 (999) OTHER
(ALL FLOORS) ALL HEATERS NO DISCONNECT
RSLV 10/27/2017 10/27/2017 11/20/2017
 
009 (999) OTHER
(BASEMENT) NO FUSE CORD FOR NEW LOADS 240.12
RSLV 10/27/2017 10/27/2017 11/20/2017