Electrical Application Details for App #: M359019
Premises: 461 WEST 23 STREET MANHATTAN BIN: 1067979     Block: 721   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 470 W 24 ST Census Tract:   93 Health Area:  5200
BOILER ROOM Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10011 Community Board:   104
DOB Cross Street(s):    9 AVENUE,    10 AVENUE
Status:   C - JOB IS SIGNED OFF 03/22/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/25/2014 9:37 AM
Application Entered:   09/25/2014 Job Start Date:   09/25/2014
Last Change:   03/22/2017 Job End Date:   03/25/2015
Appointment Status:   
Last Inspection By:   MICHAEL QUERY       On     03/13/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011991 Licensee Name: ROLAND EDWARDS
Firm: 003719 Firm Name: KRAFT ELECTRIC CORP
Firm Phone: 718-220-2260  Firm Address: 2377 WASHINGTON AVENUE..FL 1 BRONX NY 10458 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $216.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: CARL REINLIB
Owner Business Name: LODON TERRACE TOWERS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  4 # 4/0 AWG
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  100 & 200 AMPS, 30 CIR.
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  2  ST. JOHNSONS

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS          30         
Buildings Total          30           
Total Units : 38 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  WIRING TWO NEW BURNERS.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M359019
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/13/2017 03/15/2017 MQY C (60) (0) Y
INSPECTION COMMENTS: BOILERS CONTROL AND PANEL