BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M358114
Premises: 362 WEST STREET MANHATTAN BIN: 1086104     Block: 602   Lot: 7501
   
Application Completed and Certified

Filed: 1 MORTON SQUARE Census Tract:   69 Health Area:  6400
APT 7AE Admin Area:   M - MANHATTAN Inspection Area:   R
NEW YORK, NY 10014 Community Board:   102
DOB Cross Street(s):   WASHINGTON STREET,    WEST STREET
Status:   C - JOB IS SIGNED OFF 04/17/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/03/2014 3:28 PM
Application Entered:   09/03/2014 Job Start Date:   09/05/2014
Last Change:   04/17/2015 Job End Date:   10/30/2014
Appointment Status:   
Last Inspection By:   GANITIS, PHILLIP       On     04/13/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012593 Licensee Name: FARID J MARJI
Firm: 004424 Firm Name: NEW YORK EMPIRE ELECL CON
Firm Phone: 718-619-8181  Firm Address: 1236 JEROME AVENUE SERVICES INC BRONX NY 10452 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $76.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: AMY LAI
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
007  7AE    10    10  15             
Buildings Total   10    10  15                
Total Units : 35 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 04/02/2015
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REPLACEMENT OF DEVICES, REMOVAL AND REPLACEMENT OF FIXTURES. NO NEW BRANCH CIRCUITS.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M358114
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/26/2015 04/02/2015 BUR V (45) (3) Y
INSPECTION COMMENTS: LIVING ROOM LED DRIVER NOT INSPECTED
 
(2) 04/13/2015 04/17/2015 PHG C R (35) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M358114
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
KITCHEN: PLUGMOLD UNDER CABINET NOT G.F.C.I. PROTECTED.. 210.8AB
RSLV 03/26/2015 03/26/2015 04/13/2015
 
002 (999) OTHER
KITCHEN: COUNTER TOP RECEPTACLES EXCEED 20" FROM COUNTERTOP TO UN-DER CABINET AS PER 210.52C5
RSLV 03/26/2015 03/26/2015 04/13/2015
 
003 (999) OTHER
KITCHEN: SWITCH RECESS INTO UNDER CABINET WOOD NO PROTECTION PROVID-ED.. 314.20
RSLV 03/26/2015 03/26/2015 04/13/2015



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back