NYC Department of Buildings
Electrical Application Details for App #: M355489
Premises: 39 BOND STREET MANHATTAN BIN: 1084924     Block: 529   Lot: 27
   
Application Completed and Certified

Filed: 39 BOND ST Census Tract:   55.02 Health Area:  5700
4TH FLOOR Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10012 Community Board:   102
DOB Cross Street(s):   LAFAYETTE STREET,    BOWERY
Status:   C - JOB IS SIGNED OFF 02/20/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/27/2014 11:35 AM
Application Entered:   06/27/2014 Job Start Date:   06/30/2014
Last Change:   02/20/2015 Job End Date:   11/30/2014
Appointment Status:   
Last Inspection By:   RAMJAG, BUDRAM       On     02/12/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 012477 Licensee Name: VIKTOR HOMISIN
Firm: 004285 Firm Name: POWER FULL ELECTRIC, INC
Firm Phone: 917-416-3653  Firm Address: 167 DIVISION AVE GROUND FL BROOKLYN NY 11211 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $221.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   MULTI FAMILY BUILDIN
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MAYA LIN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  AWG#3/0
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  AWG #3/0
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  AWG#3,
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
004    70  45    25  70  16  10     
Buildings Total 70  45    25  70     16     10      
Total Units : 236 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 1 + New Meters 1 - Removed Meters 1 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/27/2014 Notice:  
Power Issued: 06/27/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M355489
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/12/2015 02/20/2015 BUR C E (60) (0) Y
INSPECTION COMMENTS: NONE