Premises: 69 CLINTON STREET MANHATTAN BIN: 1004232     Block: 349   Lot: 29
   
Application Completed and Certified

Filed: 69 CLINTON ST Census Tract:   30.01 Health Area:  6600
CELLAR Admin Area:   M - MANHATTAN Inspection Area:   T
NEW YORK, NY 10002 Community Board:   103
DOB Cross Street(s):   STANTON STREET,    RIVINGTON STREET
Status:   C - JOB IS SIGNED OFF 12/22/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/17/2014 7:20 PM
Application Entered:   06/17/2014 Job Start Date:   06/18/2014
Last Change:   12/22/2014 Job End Date:   06/18/2015
Appointment Status:   
Last Inspection By:   ELLIS DAVID       On     12/17/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 012089 Licensee Name: PEDRO M ABREU
Firm: 004413 Firm Name: JAMCOB ELECTRIC LLC
Firm Phone: 347-577-6644  Firm Address: 1420 WHITE PLAINS ROAD BRONX NY 10462 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $341.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: LIONEL NAZARIAN
Owner Business Name: 69 CLINTON NPG LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  3-100A SWITCH
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  1-400A SWITCH
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  3 SET 0F # 2
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  1 SET OF 3/0
D. Over 250 MCM  1  1 SET 500 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  MAIN BREAKER COMBO
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                       
Total Units : 3 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 19 #4-Wire 0 #10-Wire 0
Existing Meters 19 + New Meters 0 - Removed Meters 0 = Total Meters 19

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/17/2014 Notice: 1 - FIRST NOTICE 11/12/2014
Power Issued: 06/17/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  TO UP-GRADE ELECTRICAL SERVICE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M355035
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/03/2014 11/12/2014 EDB V G (45) (10) Y
INSPECTION COMMENTS: NO ACCESS TO WATER MAIN CONNECTION
 
(2) 12/17/2014 12/22/2014 EID C R E (45) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M355035
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
T-OUT: OPEN BOXES FOR LIGHT. AM 110.2A
RSLV 11/03/2014 11/03/2014 12/17/2014
 
002 (999) OTHER
SOUTH STORE: MAIN DISC DOUBLE LUG ON POWER. 110.14A,3B
RSLV 11/03/2014 11/03/2014 12/17/2014
 
003 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
SOUTH STORE: 100A MAIN CB UNDERSIZE WIRE. T.310.16
RSLV 11/03/2014 11/03/2014 12/17/2014
 
004 (999) OTHER
PLP: NO MAIN CB. 408.36F
RSLV 11/03/2014 11/03/2014 12/17/2014
 
005 (999) OTHER
PLP: DOUBLE LUG ON POWER. 110.14A.3B
RSLV 11/03/2014 11/03/2014 12/17/2014
 
006 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
BSMT: EL.RM. TAP FOR S,N STORE AND PLP FROM TAP OF 400A. 240.21
RSLV 11/03/2014 11/03/2014 12/17/2014
 
007 ( 24) ARMORED CABLES ARE NOT PROPERLY SECURED
BSMT: EL.RM. A/C CABLE NOT PROPERLY SECURED. 320.30
RSLV 11/03/2014 11/03/2014 12/17/2014
 
008 ( 19) DEFECTIVE WIRING IS IN USE
EL.RM: OPEN WIRING. AM.110.2A
RSLV 11/03/2014 11/03/2014 12/17/2014
 
009 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
EL.RM: NO DIRECTORY IN PANELS. 408.4
RSLV 11/03/2014 11/03/2014 12/17/2014
 
010 ( 7) EMT IS NOT PROPERLY SUPPORTED (TYPE:EMT)
BSMT: EMT NOT PROPERLY SUPPORTED (END BOX TO S.S) 358.30
RSLV 11/03/2014 11/03/2014 12/17/2014