BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Property Permits  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M354387
Premises: 124 HUDSON STREET MANHATTAN BIN: 1002166     Block: 190   Lot: 7506
   

Filed: 124 HUDSON ST Census Tract:   33 Health Area:  7700
GROUND FLOOR STORE Admin Area:   M - MANHATTAN Inspection Area:   W
NEW YORK, NY 10013 Community Board:   101
DOB Cross Street(s):   NORTH MOORE STREET,    ERICSSON PLACE
Status:   K - CLOSED/CANCELLED 06/30/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/03/2014 8:17 AM
Application Entered:   06/03/2014 Job Start Date:   06/03/2014
Last Change:   06/30/2014 Job End Date:   06/04/2014
Appointment Status:   
Last Inspection By:   ERIC HIRSCH       On     06/20/2014      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 012435 Licensee Name: FRANK V CARUSO
Firm: 004389 Firm Name: FVC ELECTRIC, INC
Firm Phone: 347-506-3990  Firm Address: 61-43 186TH STREET, SUITE 521 FRESH MEADOWS NY 11365 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
9 - OTHER
Total Fee:  $40.00
Other Work:   REMOVAL OF APPLICATIO
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   W - School
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: BRUCE RITTENBERG
Owner Business Name: TIME EQUITIES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND  GYM                     
Buildings Total                       
Total Units : 1 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 4 #4-Wire 0 #10-Wire 0
Existing Meters 4 + New Meters 1 - Removed Meters 1 = Total Meters 4

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/03/2014 Notice:  
Power Issued: 06/03/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  FILING JOB NEVER STARTED APPLICATION #M342354 INSPECTORP PORAZZO REQUEST TO FILE AND REMOVE FOR NO SERVICE WORK EVER STARTED

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M354387
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/20/2014 06/30/2014 ECH K (20) (0) Y
INSPECTION COMMENTS: CONTRACTOR CLAIMS WORK NEVER DONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.