Electrical Application Details for App #: M352310
Premises: 1379 LEXINGTON AVENUE MANHATTAN BIN: 1048274     Block: 1519   Lot: 52
  Printable (PDF) version of this Permit  

Filed: 1379 LEXINGTON AV Census Tract:   148.02 Health Area:  3600
GROUND FLOOR Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10128 Community Board:   108
DOB Cross Street(s):   EAST 90 STREET,    EAST 91 STREET
Status:   N - NO ACCESS 06/05/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/07/2014 10:37 PM
Application Entered:   04/07/2014 Job Start Date:   04/08/2014
Last Change:   06/05/2015 Job End Date:   06/23/2014
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   GANITIS, PHILLIP       On     06/01/2015      
Field Disp:   N - NO ACCESS
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  Y - PARTLY REMOVED

License #: 012151 Licensee Name: ANTHONY DAIDONE
Firm: 003853 Firm Name: E & M ELEC'L CONTR'G COR
Firm Phone: 718-849-0528  Firm Address: 74-10 69 ROAD MIDDLE VILLAGE NY 11379 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $55.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: FOURMAN SEM
Owner Business Name: MATRIX REALTY CO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  4#2
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 04/07/2014 Notice: 1 - FIRST NOTICE 06/11/2014
Power Issued: 04/07/2014 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M352310
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/03/2014 06/11/2014 IOS A G (40) (2) Y
INSPECTION COMMENTS: DISCONNECT AND METER LOCATED IN BASEMENT OF 1377 LEXINGTON AVE
 
(2) 12/11/2014 12/17/2014 UMS J Y E (30) (0) Y
INSPECTION COMMENTS: APP NEEDS TO BE AMENDED. DISCONNECT SWITCH AND PANEL NOT INCLUDED IN APPLICATION
 
(3) 06/01/2015 06/05/2015 PHG N (40) (0) Y
INSPECTION COMMENTS: CALLED CANCELED NO SHOW

OBJECTION FOR APPLICATION #: M352310
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
BASEMENT DISCONNECT FOR APT. 2C IS LOCATED ABOVE 6 FEET 7INCHES404.8(A)
RSLV 06/03/2014 06/03/2014 12/11/2014
 
002 ( 6) FEEDER DIAGRAM DID NOT ACCOMPANY APPLICATION FOR INSPECTION
BASEMENT LOAD CALCULATIONS REQUIRED FOR 200A SWITCHFEED ALL APARMENTS INCLUDING APT 2C
OPEN 06/03/2014 12/11/2014