| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
2 |
20 CIRCUIT MAIN LUG |
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(999) |
OTHER 109/H: NO CLEARANCE FOR PANEL IN KITCHEN. 110.26 |
RSLV |
05/06/2014 |
06/11/2014 |
07/28/2014 |
| |
| 002 |
(999) |
OTHER 109/H: NO HANDLE TIES PROVIDED FOR MULTIWIRE CKT. 210.4 |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 003 |
( 46) |
PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY 109/H: KITCHEN PANEL HAS NO DIRECTORY - BOTH. 408.4 |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 004 |
( 59) |
AFCI PROTECTION HAS NOT BEEN PROVIDED 109/H: NO A.F.C.I.PROVIDED IN ALL APT. 210.12B |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 005 |
(999) |
OTHER 10/9/H: PANEL LOCATED IN CLOTHES CLOSET. 240.24D |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 006 |
(999) |
OTHER 10/9/H: BATHROOM LIGHT HUNG OVER BATH TUB. 410.10D |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 007 |
( 29) |
OUTLET BOXES ARE NOT COVERED 10/9/H: PULL BOX IN GUEST ROOM HAS NO COVER. 314.25 |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 008 |
( 25) |
ARMORED CABLES ARE NOT PROPERLY TERMINATED 10/5H: BX NOT TERMINATED BY CONDENSER. 320.40 |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 009 |
(999) |
OTHER 10/9/H: NO DISCONNECT SW FOR CONDERSER. 430.75 |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 010 |
( 34) |
KNOCKOUTS ARE NOT CLOSED IN PANEL BOX 10/5/H: KO MISSING IN KITCHEN PANEL. 110.12 |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 011 |
( 27) |
ARMORED CABLES INSTALLED WITHOUT INSULATING BUSHINGS 10/9/H: OPEN BOX IN MASTER BATHROOM. 314.25 |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 012 |
( 22) |
FIXED EQUIPMENT IS NOT PROPERLY GROUNDED 10/9/H: NO PROPER CONNECTON IN KITCHEN ISLAND FROM BX TO WIRE MOLDMOUSE TRAP. 250.112 |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |
| |
| 013 |
(999) |
OTHER 10/9/H: 2 CABLES IN GEM BOX IN KITCHEN ISLAND. 314.16A |
RSLV |
05/06/2014 |
05/06/2014 |
06/11/2014 |