BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M351624
Premises: 26 EAST 91 STREET MANHATTAN BIN: 1047004     Block: 1502   Lot: 56
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 26 E 91 ST Census Tract:   150.02
GROUND FL Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10128 Community Board:   108
Special Place Name:   STORE FRONT
DOB Cross Street(s):    5 AVENUE,    MADISON AVENUE
Status:   C - JOB IS SIGNED OFF 07/09/2019
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   05/21/2015 Job Start Date:   05/18/2015
Last Change:   07/09/2019 Job End Date:   12/20/2015
Appointment Status:    Complaint Number:    1367604
Last Inspection By:   DIAMOND, R.       On     06/26/2019      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010714 Licensee Name: FRANK MARCELLINO
Firm: 000936 Firm Name: MARCEL ELEC'L CONTRG CORP
Firm Phone: 718-792-4423  Firm Address: 1140 BRONX RIVER AVENUE BRONX NY 10472 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $54.00
Hurricane Sandy Damage:   No
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: EAT MADISON LLC
Authorized Representative:  RICHARD LEWIS
Relationship To Owner:   ARCHITECT


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  12  12             
Buildings Total 12  12                
Total Units : 38 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: C - CALL TO OFFICE 09/25/2018
Power Issued: Response: F - FILED TO REMOVE OBJECTION 05/21/2015

Follow-Up: X - FILED APPL,NOW CLOSED 05/21/2015
Contractor's Comments:  NO APP ON FILE FOR TEMP WIRINGREMOVING ECB VIOLATION NUMBERS #35038859Y #35038860LAKA 1270 MADISON AVE RE:M356921

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M351624
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/19/2014 03/20/2014 RID W (15) (2)
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 09/25/2018 09/25/2018 STP V X (55) (10)
INSPECTION COMMENTS: FAIL. LICENSEE TO REVIEW JOB BEFORE RE INSPECTION. DID NOT INSPECT INSPECT AC MOTORS AND FEED FOR PANEL. PLEASE NOTE TWO ECB ATTACHED
 
(3) 06/26/2019 06/27/2019 RDI C R (20) (0)
INSPECTION COMMENTS: INSPECTION COMPLETE - TWO ECB'S REMOVED

OBJECTION FOR APPLICATION #: M351624
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 3) APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE
(ALL FLOORS) THE ENTIRE STORE FRONTCOM: REMOVED & INSTALLED TEMPORARY WIRING, BRANCH CIRCUIT WIRING
RSLV 03/19/2014 03/19/2014 06/26/2019
 
002 ( 3) APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE
(ALL FLOORS) RECEPTACLE OUTLETS, LIGHTING FIXTURESTHIS IS NOT A FINAL INSPECTION. SEE THIS COMPLAINT #1367604
RSLV 03/19/2014 03/19/2014 06/26/2019
 
003 (999) OTHER
(FLOOR: 002) KITCHEN EMT NEEDS STRAP 358.30
RSLV 09/25/2018 09/25/2018 06/26/2019
 
004 (999) OTHER
(FLOOR: 002) CEILING LIGHT KITCHEN WIRED WITH FLEX CORD 400.8
RSLV 09/25/2018 09/25/2018 06/26/2019
 
005 (999) OTHER
(FLOOR: 002) SCONCE LIGHTS GROUNDS CUT 250 410.44
RSLV 09/25/2018 09/25/2018 06/26/2019
 
006 (999) OTHER
(FLOOR: 002) EXPOSED WIRING METHOD COOKING HOOD 300.22
RSLV 09/25/2018 09/25/2018 06/26/2019
 
007 (999) OTHER
(FLOOR: 002) HANDLE TIES FOR PANEL 210.4
RSLV 09/25/2018 09/25/2018 06/26/2019
 
008 (999) OTHER
(FLOOR: 002) DISHWASHER DISCONNECT ACCESS 404.8 110.26
RSLV 09/25/2018 09/25/2018 06/26/2019
 
009 (999) OTHER
(ALL FLOORS) UPSTAIRS KITCHEN AND FRONT COVER MISSING 314.25
RSLV 09/25/2018 09/25/2018 06/26/2019
 
010 (999) OTHER
(GROUND FLOOR) KO OPEN IN PANEL 110.12
RSLV 09/25/2018 09/25/2018 06/26/2019
 
011 (999) OTHER
(GROUND FLOOR) GFI NEEDED WHERE MISSING KITCHEN AREA 210.8
RSLV 09/25/2018 09/25/2018 06/26/2019
 
012 (999) OTHER
(GROUND FLOOR) EXT COLLAR FOR BOX SET IN WOOD 314.20
RSLV 09/25/2018 09/25/2018 06/26/2019