Premises: 63 EAST 79 STREET MANHATTAN BIN: 1046440     Block: 1491   Lot: 28
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 63 E 79 ST Census Tract:   142 Health Area:  3600
O/D Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10075 Community Board:   108
DOB Cross Street(s):   MADISON AVENUE,    PARK AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/17/2014 11:50 AM
Application Entered:   03/17/2014 Job Start Date:   04/02/2014
Last Change:   08/22/2025 Job End Date:   05/02/2014
Appointment Status:   
Last Inspection By:   URIM SYLA       On     10/31/2014      
Field Disp:   A - OBJCTN ISSD: JOB COMPLETE
Energize Recommendation:  
Objection Disposition:  

License #: 011917 Licensee Name: ALTAF H SYED-NAQVI
Firm: 003528 Firm Name: ALSON ELEC'L CONTR. INC
Firm Phone: 718-435-1677  Firm Address: 1253 ROCKAWAY AVENUE BROOKLYN NY 11236 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
W - SIDEWALK SHED WIRING & LIGHTING
Total Fee:  $40.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   D4
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: LAKHWINDER SINGH
Owner Business Name: METRO CONTRACTING INC
Authorized Representative:  S KULANDAI
Relationship To Owner:   F.R


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
SWK                     
Buildings Total                     
Total Units : 5 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: 1 - FIRST NOTICE 11/10/2014
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  LIGHTS IN COMPLIANCE NYC CC$3307.6.5 SHED 37 LF PER PLAN.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M351497
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/31/2014 11/10/2014 UMS A (15) (3) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M351497
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
DEFECTIVE WIRING IN USE.EXPOSED THHN WIRE RUN FROM OUTDOOR SPLICEBOX TO G.F.I. AMEND 110.2
OPEN 10/31/2014 10/31/2014
 
002 (999) OTHER
G.F.I. NOT GROUNDED PROPERLY. 406.3(B)
OPEN 10/31/2014 10/31/2014
 
003 (999) OTHER
SHED LIGHTS NOT GORUNDED PROPERLY. 410.40
OPEN 10/31/2014 10/31/2014