Electrical Application Details for App #: M351411
Premises: 52 CARMINE STREET MANHATTAN BIN: 1008356     Block: 527   Lot: 56
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 52 CARMINE ST Census Tract:   67 Health Area:  6400
ENTIRE Admin Area:   M - MANHATTAN Inspection Area:   R
NEW YORK, NY 10014 Community Board:   102
DOB Cross Street(s):   BLEECKER STREET,    BEDFORD STREET
Status:   C - JOB IS SIGNED OFF 05/17/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/13/2014 7:26 PM
Application Entered:   03/13/2014 Job Start Date:   03/14/2014
Last Change:   05/17/2016 Job End Date:   08/10/2014
Appointment Status:   
Last Inspection By:   MODELFINO, CARL C       On     05/13/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012008 Licensee Name: JAROSLAW K KURACH
Firm: 003679 Firm Name: BELMONT ELECTRICAL, INC
Firm Phone: 646-484-6641  Firm Address: 42 WEST 38TH STREET, STE 503 NEW YORK NY 10018 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $659.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (2  Stores, 14 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: RAYMOND VAZLOPEZ
Owner Business Name: RVL PROPERTIES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  400A, 3PHASE, 120/208
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  14  6/3 THHN BX
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  4-350MCM THHN
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  15  20CKT, 120/208
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001                       
002                       
003                       
004                       
005                       
Buildings Total   28                      
Total Units : 28 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 17 #4-Wire 0 #10-Wire 0
Existing Meters 17 + New Meters 17 - Removed Meters 17 = Total Meters 17

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/13/2014 Notice: 1 - FIRST NOTICE 03/08/2016
Power Issued: 03/13/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALLATION OF: NEW SERVICE, NEW RISER, NEW PANEL IN EACH APARTMENT, 2 GFCI'S IN EACH KITCHEN. ALL OTHER WIRING TO REMAIN EXISTING.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M351411
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/07/2016 03/08/2016 TOR V (60) (5)
INSPECTION COMMENTS: CONTRACTOR DID SERVICE AND 2 RECEPTACLES IN KITCHEN PLUS ELECTRIC STOVE. OTHER JOB BY OTHERS.
 
(2) 05/13/2016 05/17/2016 MLF C R (30) (0)
INSPECTION COMMENTS: ALL OBJECTIONS RESOLVED

OBJECTION FOR APPLICATION #: M351411
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
(ALL FLOORS) ALL ELECTRIC STOVES NEUTRAL BOND TO ENCLOSURE
RSLV 03/07/2016 03/07/2016 05/13/2016
 
002 ( 19) DEFECTIVE WIRING IS IN USE
(ALL FLOORS) NEUTRAL GROUNDED TO ENCLOSURE
RSLV 03/07/2016 03/07/2016 05/13/2016
 
003 ( 29) OUTLET BOXES ARE NOT COVERED
(ALL FLOORS) J BOXES NOT COVER
RSLV 03/07/2016 03/07/2016 05/13/2016
 
004 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(ALL FLOORS) NO PANEL DIRECTORY
RSLV 03/07/2016 03/07/2016 05/13/2016
 
005 (999) OTHER
(GROUND FLOOR) SERVICE NO ARC FLASH WARNING LABEL PROVIDED 110.16
RSLV 03/07/2016 03/07/2016 05/13/2016