| NYC Department of Buildings | ||
| Electrical Application Details for App #: M351009 | ||
| Premises: 89 EAST 2 STREET MANHATTAN | BIN: 1005735 Block: 429 Lot: 9 |
| Application Completed and Certified | ||
| Filed: | 89 E 2 ST | Census Tract: 30.02 | Health Area: 6600 | |
| BASEMENT | Admin Area: M - MANHATTAN | Inspection Area: T | ||
| NEW YORK, NY 10009 | Community Board: 103 | |||
| DOB Cross Street(s): 1 AVENUE, AVENUE A | |||
| Status: C - JOB IS SIGNED OFF 04/30/2014 | |||
| Request Type: A - APPLICATION | eFiled: YES | Permit Issued: 03/04/2014 4:09 PM | |
| Application Entered: 03/04/2014 | Job Start Date: 03/04/2014 | ||
| Last Change: 04/30/2014 | Job End Date: 03/04/2015 | ||
| Appointment Status: | |||
| Last Inspection By: ROGALEWSKI, M On 04/29/2014 | |||
| Field Disp: C - INSPECTION PASSED | |||
| Energize Recommendation: E - ISSUE POWER AUTH | |||
| Objection Disposition: | |||
| License #: | 010695 | Licensee Name: | JOE YUK LEE | |
| Firm: | 002279 | Firm Name: | UNITED ELEC'L CONT'G CORP | |
| Firm Phone: | 212-777-8899 | Firm Address: | 45-04 162ND STREET, SUITE 205 FLUSHING NY 11385 | |
| Work Started or Filed by Others: NO | ||||||||
| Work Category: R - REHABILITATION | Work To Be Done:
1 - SERVICE WORK/NOTIFY UTILITY |
Total Fee: $135.00 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: NO | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: No | ||||||||
| Building Used As: K - Store | |||||||
| Store / Other: SMOKE SHOP | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | MOHAMED RAMADON | ||||||
| Owner Business Name: | HADE BADE | ||||||
| Authorized Representative: | |||||||
| Relationship To Owner: | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| Buildings Total | ||||||||||||
| Total Units : 0 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 0 | #4-Wire | 1 | #10-Wire | 0 | |
| Existing Meters | 0 | + New Meters | 0 | - Removed Meters | 0 | = Total Meters | 0 |
| Power Auth Flag: | I - ISSUED | Objection Flag: | |
| Power Requested: | 03/04/2014 | Notice: | |
| Power Issued: | 03/04/2014 | Response: |
| Follow-Up: | K - (CLOSED) | ||
| Contractor's Comments: | |||
|
|
| INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |
APPT FLAG |
| (1) | 04/29/2014 | 04/30/2014 | MIR | C | E | (25) | (0) | Y | ||
| INSPECTION COMMENTS: | NONE | |||||||||