Electrical Application Details for App #: M349046
Premises: 372 5 AVENUE MANHATTAN BIN: 1015898     Block: 837   Lot: 40
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 372 5 AV Census Tract:   84 Health Area:  5200
7A Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10018 Community Board:   105
DOB Cross Street(s):    5 AVENUE,    AVENUE OF THE AMERICAS
Status:   C - JOB IS SIGNED OFF 04/13/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/08/2014 3:30 PM
Application Entered:   01/08/2014 Job Start Date:   01/08/2014
Last Change:   04/13/2016 Job End Date:   01/07/2015
Appointment Status:   
Last Inspection By:   BERGMAN EDUARD       On     04/12/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011878 Licensee Name: EDGAR LEVENSTEIN
Firm: 003500 Firm Name: CONTACT PLUS ELEC'L CORP
Firm Phone: 718-254-0291  Firm Address: 2922 SHELL ROAD BROOKLYN NY 11224 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $52.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOSEPH KLAYNBERG
Owner Business Name: 372 FIFTH AVE OWNERS INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
007  7A  14  20  14             
Buildings Total 14  20  14                
Total Units : 58 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 08/29/2014
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M349046
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/22/2014 08/29/2014 EDB A (55) (6) Y
INSPECTION COMMENTS: NONE
 
(2) 04/12/2016 04/13/2016 EDB C R (60) (0)
INSPECTION COMMENTS: P

OBJECTION FOR APPLICATION #: M349046
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
(ALL FLOORS)PANEL 40 A CB FOR OVEN SPLICE W/ #12AWG IN OVEN CABINET (KITCHENAREA) AM 1102A, T 310.16
RSLV 08/22/2014 08/22/2014 04/12/2016
 
002 ( 16) DEFECTIVE LIGHTING FIXTURES ARE IN USE
(ALL FLOORS) KITCHEN OPEN WIRING ON LIGHT FIXTURE AM 110.2A
RSLV 08/22/2014 08/22/2014 04/12/2016
 
003 (109) SUFFICIENT WORK SPACE IS NOT PROVIDED/MAINTAINED
(ALL FLOORS) KITCHEN NO WORKING SPACE IN FRONT OF PANEL 110.26
RSLV 08/22/2014 08/22/2014 04/12/2016
 
004 (211) RECEPTACLE IS NOT PROPERLY BONDED/GROUNDED
(ALL FLOORS) T-OUT RECEPTICAL NOT PROPERLY GND 250.146
RSLV 08/22/2014 08/22/2014 04/12/2016
 
005 (999) OTHER
(ALL FLOORS) T-OUT RECEPTICAL MORE THAN 1/4" FROM WALL 314.20,21
RSLV 08/22/2014 08/22/2014 04/12/2016
 
006 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
(ALL FLOORS) PANEL K/O MISSING
RSLV 08/22/2014 08/22/2014 04/12/2016